TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | To set which report would be sent in Report group 1 | 1 | Send Meter Report of Voltage | |
2 | Send Meter Report of Current | ||||
4 | Send Meter Report of Watt | ||||
8 | Send Meter Report of kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | To set which report would be sent in Report group 2 | 1 | Send Meter Report of Voltage | |
2 | Send Meter Report of Current | ||||
4 | Send Meter Report of Watt | ||||
8 | Send Meter Report of kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | To set which report would be sent in Report group 3 | 1 | Send Meter Report of Voltage | |
2 | Send Meter Report of Current | ||||
4 | Send Meter Report of Watt | ||||
8 | Send Meter Report of kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Set the time interval of sending Report | 1 to 2147483647 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | Set the time interval of sending Report | 1 to 2147483647 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | Set the time interval of sending Report | 1 to 2147483647 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Configure the output load status after re-power on | 0 (Default) |
The last status before the power outage. | |
1 | Always on | ||||
2 | Always off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
243 | 2 | Pin code | 0 to 65535 (Default) |
The available range of the Pin code is 0 to 65535. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/disable Configuration Locked | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset the Plug | 1 | Reset all configuration parameters to default. | |
1431655765 | Reset the Plug to factory default | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Current Overload Protection. | 0 | Disabled | |
1 (Default) |
Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | To set which notification would be sent to the associated nodes in association group 1 | 0 (Default) |
Nothing | |
1 | Hail CC | ||||
2 | Basic Report CC | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
81 | 1 | Configure the state of LED | 0 (Default) |
Energy mode. The LED will follow the status (on/off). | |
1 | Momentary indicate mode. When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action. | ||||
2 | Night light mode. The LED will remain the state that is set via the Multilevel Switch Set CC or Color Switch Set CC. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
82 | 4 | Set the time of LED state when it is in Night light mode | 0 to 59 | time of OFF state (minute) | |
256 to 279 | time of OFF state (hour) | ||||
65536 to 65595 | time of ON state (minute) | ||||
16777216 to 16777239 | time of ON state (hour) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
90 | 1 | Enable/disable the parameter 91 and 92 | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
91 | 2 | Induce an automatic report | 0 to 32767 (Default) |
The threshold can be set from 0 to 32767 watt. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
92 | 1 | Induce an automatic report | 0 to 100 (Default) |
The threshold can be set from 0 to 100%. | |