Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Plug (FT145-K19)

Z-Wave Certification Number: ZC10-17105790


Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 To set which report would be sent in Report group 1 1 Send Meter Report of Voltage
  2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8 Send Meter Report of kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which report would be sent in Report group 2 1 Send Meter Report of Voltage
  2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8 Send Meter Report of kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 To set which report would be sent in Report group 3 1 Send Meter Report of Voltage
  2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8 Send Meter Report of kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the time interval of sending Report 1 to 2147483647
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the time interval of sending Report 1 to 2147483647
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the time interval of sending Report 1 to 2147483647
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Configure the output load status after re-power on 0
(Default)
The last status before the power outage.
  1 Always on
  2 Always off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

243 2 Pin code 0 to 65535
(Default)
The available range of the Pin code is 0 to 65535.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/disable Configuration Locked 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset the Plug 1 Reset all configuration parameters to default.
  1431655765 Reset the Plug to factory default

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Current Overload Protection. 0 Disabled
  1
(Default)
Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 To set which notification would be sent to the associated nodes in association group 1 0
(Default)
Nothing
  1 Hail CC
  2 Basic Report CC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

81 1 Configure the state of LED 0
(Default)
Energy mode. The LED will follow the status (on/off).
  1 Momentary indicate mode. When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action.
  2 Night light mode. The LED will remain the state that is set via the Multilevel Switch Set CC or Color Switch Set CC.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

82 4 Set the time of LED state when it is in Night light mode 0 to 59 time of OFF state (minute)
  256 to 279 time of OFF state (hour)
  65536 to 65595 time of ON state (minute)
  16777216 to 16777239 time of ON state (hour)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Enable/disable the parameter 91 and 92 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

91 2 Induce an automatic report 0 to 32767
(Default)
The threshold can be set from 0 to 32767 watt.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

92 1 Induce an automatic report 0 to 100
(Default)
The threshold can be set from 0 to 100%.