Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | ENABLE/DISABLE BASIC SET COMMAND | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | VALUE OF THE BASIC SET | 0 (Default) |
Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is canceled. | |
1 | Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is canceled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Set flooding alarm interval (Minute) | 0 | Disable flooding alarm | |
-128 to 127 (Default) |
The higher the value, the long the report periodically - in hexadecimal values from 0x01 to 0xFF, or 1 to 255 if your controller allows unsigned decimal values. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | ENABLE/DISABLE SHOCK ALARM | 0 to 1 (Default) |
when the value is 0, the product will not sends a vibration alarm after moving or shaking; when the value is 1, the product will sends a vibration alarm after moving or shaking | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Temperature report time (minute) | -128 to 127 (Default) |
the higher the value ,the long the report time | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 2 | Set the high temperature alarm trigger value | -670 to 2570 (Default) |
the larger the value , the higher the high temperature(US) | |
-550 to 1250 (Default) |
the larger the value , the higher the high temperature(other) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 2 | Set the low temperature alarm trigger value | -670 to 2570 (Default) |
the smaller the value , the lower the low temperature(US) | |
-550 to 1250 (Default) |
the smaller the value , the lower the low temperature(other) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Enable/Disable blinking LED when alarm being triggered | 0 to 1 (Default) |
when the value is 0, the product will not alarm when being triggered; when the value is 1, the product will alarm when being triggered | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
32 | 1 | LEVEL OF LOW BATTERY | 10 to 50 (Default) |
Set the trigger value for the low battery alarm | |