TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Flood Sensor (HKZW-FLD01)

Z-Wave Certification Number: ZC10-17125894


Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 ENABLE/DISABLE BASIC SET COMMAND 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 VALUE OF THE BASIC SET 0
(Default)
Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is canceled.
  1 Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is triggered. Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is canceled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 Set flooding alarm interval (Minute) 0 Disable flooding alarm
  -128 to 127
(Default)
The higher the value, the long the report periodically - in hexadecimal values from 0x01 to 0xFF, or 1 to 255 if your controller allows unsigned decimal values.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 ENABLE/DISABLE SHOCK ALARM 0 to 1
(Default)
when the value is 0, the product will not sends a vibration alarm after moving or shaking; when the value is 1, the product will sends a vibration alarm after moving or shaking

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 Temperature report time (minute) -128 to 127
(Default)
the higher the value ,the long the report time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 2 Set the high temperature alarm trigger value -670 to 2570
(Default)
the larger the value , the higher the high temperature(US)
  -550 to 1250
(Default)
the larger the value , the higher the high temperature(other)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 2 Set the low temperature alarm trigger value -670 to 2570
(Default)
the smaller the value , the lower the low temperature(US)
  -550 to 1250
(Default)
the smaller the value , the lower the low temperature(other)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Enable/Disable blinking LED when alarm being triggered 0 to 1
(Default)
when the value is 0, the product will not alarm when being triggered; when the value is 1, the product will alarm when being triggered

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 1 LEVEL OF LOW BATTERY 10 to 50
(Default)
Set the trigger value for the low battery alarm