TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Association LED | 0 (Default) |
Turns Central LED OFF | |
1 to 255 | Turns Central LED ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Behavior of LED in Repose | 0 (Default) |
Left and Right LEDs OFF | |
1 to 255 | Left and Right LEDs ON at 20percent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Lock Input | 0 (Default) |
Local action enabled | |
1 to 255 | Local action locked | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Reset Default | 39015 | Factory reset | |
17170 | Configuration values are restored | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Lock Manual Assocaition | 0 (Default) |
Hold press of 10sec to 30sec starts manual association of devices to group 2 | |
1 to 255 | Hold press of 10sec to 30sec sends a Node Info | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Press Action | 0 | short press switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes. The touch area does not work | |
1 | Short press activates those associated by sending Basic Set to 0xFF | ||||
2 | Short press deactivates those associated by sending Basic Set to 0x00 | ||||
3 | Short Press UP always activates those associated with the last power on by sending a Basic Set 0xFF. Short Press DOWN always deactivates those associated by sending a Basic Set to 0x00. | ||||
4 | Short Press always turn on the associated nodes by sending a Basic Set to 0xFF. Press from 2sec to 10sec always turns off the associated nodes by sending a Basic Set to 0x00 | ||||
6 | Short pressi on UP Area, if controlled device/s already have the value set on Config Param 26, Basic Set 0x00 is sent and UP and DOWN LEDs are turned off; Otherwise Basic Set with value (Param 26) is sent and UP LED light up for 5 sec. After short pressing on DOWN Area, if controlled device/s already have the value set on Config Param 25, Basic Set 0x00 is sent and UP | ||||
7 (Default) |
the key works as described on keypad use and feedbaks | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Identify | 1 to 255 | Central LED performs a fast blink | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 2 | Device State | 0 to 99 (Default) |
Load is OFF or sunblind is stopped with diming value or position x | |
256 to 355 | Load is ON or sunblind is going DOWN with diming value or position x | ||||
512 to 611 | Load is ON or sunblind is going UP with diming value or position x | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
25 | 1 | Left Side Value | 0 to 99 (Default) |
Value used as DOWN side value when Parameter 20 value is 6 in order to set the loat to the value | |
255 | Value used as UP side value when Parameter 20 value is 6 in order to Activate Load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
26 | 1 | Right Side Value | 0 to 99 | Value used as UP side value when Parameter 20 value is 6 in order to Set Load to this value | |
255 (Default) |
Value used as UP side value when Parameter 20 value is 6 in order to Activate Load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Lock Hold Press | 0 (Default) |
Hold press is available | |
1 to 255 | Hold Press is Locked | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
28 | 1 | Consult on Touch | 0 | Device must receive reports about controlled device state. | |
1 to 255 (Default) |
Device consults the device state once keypad detects touch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
29 | 1 | Send Central Scene | 0 | Device does not sends Central Scene Notifications | |
1 to 255 (Default) |
Device sends Central Scene Notifications is no devices are added to group 2 | ||||