Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: S100 Master Roller Dimmer iO (10002021-13X)

Z-Wave Certification Number: ZC10-18026013


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Association LED 0
(Default)
Turns Central LED OFF
  1 to 255 Turns Central LED ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Behavior of LED in Repose 0
(Default)
Central LED OFF
  1 to 255 Central LED ON at 20percent

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Lock Input 0
(Default)
Local control is available
  1 to 255 Local control is locked

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Reset Default 17170 Configuration values are restored
  39015 Factory reset

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Lock Manual Association 0
(Default)
Hold press of 10sec to 30sec starts manual association of devices to group 2
  1 to 255 Hold press of 10sec to 30sec sends a Node Info

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 Press Action 0 Short press switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes.
  1 Short press activates those associated by sending Basic Set to 0xFF
  2 Short press deactivates those associated by sending Basic Set to 0x00
  4 Short Press always turn on the associated nodes by sending a Basic Set to 0xFF. Press from 2sec to 10sec always turns off the associated nodes by sending a Basic Set to 0x00
  5
(Default)
When Short press Master inverts the load state via Basic Set, When the slider is enabled and load is ON, Multilevel Sets are sent to modify the dimming value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Identify 1 to 255 Central LED performs a fast blink

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Device State 0 to 99
(Default)
Load is OFF or sunblind is stopped with diming value or position x
  256 to 355 Load is ON or sunblind is going DOWN with diming value or position x

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Lock Hold Press 0
(Default)
Hold press is available
  1 to 255 Hold Press is Locked

Parameter Number

Parameter Size

Parameter Name

Parameter Values

28 1 Consult on Touch 0 Device must receive reports about controlled device state
  1 to 255
(Default)
Device consults the device state once keypad detects touch

Parameter Number

Parameter Size

Parameter Name

Parameter Values

29 1 Send Central Scene 0 Device does not sends Central Scene Notifications
  1 to 255
(Default)
Device sends Central Scene Notifications is no devices are added to group 2