Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Association LED | 0 (Default) |
Turns Central LED OFF | |
1 to 255 | Turns Central LED ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Behavior of LED in Repose | 0 (Default) |
Central LED OFF | |
1 to 255 | Central LED ON at 20percent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Lock Input | 0 (Default) |
Local control is available | |
1 to 255 | Local control is locked | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Reset Default | 17170 | Configuration values are restored | |
39015 | Factory reset | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Lock Manual Association | 0 (Default) |
Hold press of 10sec to 30sec starts manual association of devices to group 2 | |
1 to 255 | Hold press of 10sec to 30sec sends a Node Info | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Press Action | 0 | Short press switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes. | |
1 | Short press activates those associated by sending Basic Set to 0xFF | ||||
2 | Short press deactivates those associated by sending Basic Set to 0x00 | ||||
4 | Short Press always turn on the associated nodes by sending a Basic Set to 0xFF. Press from 2sec to 10sec always turns off the associated nodes by sending a Basic Set to 0x00 | ||||
5 (Default) |
When Short press Master inverts the load state via Basic Set, When the slider is enabled and load is ON, Multilevel Sets are sent to modify the dimming value. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Identify | 1 to 255 | Central LED performs a fast blink | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Device State | 0 to 99 (Default) |
Load is OFF or sunblind is stopped with diming value or position x | |
256 to 355 | Load is ON or sunblind is going DOWN with diming value or position x | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Lock Hold Press | 0 (Default) |
Hold press is available | |
1 to 255 | Hold Press is Locked | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
28 | 1 | Consult on Touch | 0 | Device must receive reports about controlled device state | |
1 to 255 (Default) |
Device consults the device state once keypad detects touch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
29 | 1 | Send Central Scene | 0 | Device does not sends Central Scene Notifications | |
1 to 255 (Default) |
Device sends Central Scene Notifications is no devices are added to group 2 | ||||