Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: S100 Socket iO (10002041-13X )

Z-Wave Certification Number: ZC10-18026012


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Association LED 0
(Default)
Turns Central LED OFF
  1 to 255 Turns Central LED ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Delay ON 0
(Default)
Delay is disabled
  1 to 127 Sets the delay in seconds from 1 to 127
  256 to 254 Sets the delay in minutes from 1 to 127

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Activation Time 0
(Default)
Time is disabled
  1 to 127 Time is set in seconds from 1 to 127
  128 to 254 Time is set in minutes from 1 to 127

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Behavior of LED in Repose 0
(Default)
LED1 remains OFF and only informs of load state during 5 sec. after pressing the button.
  1 to 255 LED1 always shows the load state

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Lock Input 0
(Default)
Local control is available
  1 to 255 Local control is locked

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Reset Default 17170 Configuration values are restored
  39015 Factory reset

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 1 Delay OFF 0
(Default)
Delay is disabled
  1 to 127 Sets the delay in seconds from 1 to 127
  128 to 254 Sets the delay in minutes from 1 to 127

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 PostReset State 0 After a reset the load starts Off
  1 to 255
(Default)
After a reset the load recovers the last value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 Press Action 0
(Default)
Short press toggles the load
  1 Short press activates the load
  2 Short press deactivates the load

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Identify 1 to 255 Central LED performs a fast blink

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Device State 0 Load is OFF
  511 Load is ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Lock Hold Press 0
(Default)
Hold press is available
  1 to 255 Hold Press is Locked

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Beacon 0
(Default)
Disables the beacon
  1 to 99 Sets the intensity of the beacon LEDs