There are over 4407 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Watt Meter Report Period | 1 to 32767 (Default) |
720*5s=3600s=1hour | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Existence of Endpoint3 | 1 (Default) |
1 : Endpoint3 exist | |
2 | 2 : No Endpoint3 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | KWH Meter Report Period | 1 to 32767 (Default) |
6*10min= 1 hour | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Selected Relay | 1 | 1:Relay1 | |
2 | 2:Relay2 | ||||
3 (Default) |
3:Relay1 & Relay2 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Edge and Pulse mode | 1 (Default) |
1:Edge mode | |
2 | 2:Pulse mode | ||||
3 | 3:Edge-Toggle mode | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 2 | Threshold of current for Load Caution | 10 to 750 (Default) |
750*0.01A = 7.5A | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Threshold of KWh for Load Caution | 1 to 10000 (Default) |
10000 * 1KWh=10000KWh | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Restore switch state mode | 0 | 0 : Switch off | |
1 (Default) |
1 : Last switch state | ||||
2 | 2 : Switch on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Auto off timer | 0 (Default) |
0 : Disable auto off function | |
1 to 32767 | 1-0x7FFF : 1s ~ 32767s | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | RF off command mode | 0 (Default) |
0 : Switch off | |
1 | 1 : Ignore | ||||
2 | 2 : Switch toggle | ||||
3 | 3 : Switch on | ||||