Z-Wave Products

There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Multifunction Switch (FMS)

Z-Wave Certification Number: ZC10-18026000


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Dimming Speed 30 to 32767
(Default)
Dimmer Speed in 1/100th of a Second

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Dimmer Mode 0 to 1
(Default)
Dimmer Operation Mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Maximum Level 1 to 99
(Default)
Maximum Dimmer Level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Minimum Level 1 to 99
(Default)
Minimum Dimmer Level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Button Mode 0 to 4
(Default)
Set Button Mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Light Zone Control Mode 0 to 1
(Default)
Common Mode for all Light Zones
  2 to 30 Switch Mode for individual Light Zones

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 Back Unit Role 0 to 2
(Default)
Selected Back Unit Role

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Back Unit Light Zone 1 to 4
(Default)
Selected Back Unit Light Zone

Parameter Number

Parameter Size

Parameter Name

Parameter Values

240 1 Floor Sensor Temperature Offset -128 to 127
(Default)
Temperature Offset in 1/10th of a degree Celcius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

241 1 Room Sensor Temperature Offset -128 to 127
(Default)
Temperature Offset in 1/10th of a degree Celcius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 2 Thermostat Set Point Max 0 to 500
(Default)
Set Point Max in 1/10th of a degree Celcius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 2 Thermostat Set Point Min 0 to 500
(Default)
Set Point Min in 1/10th of a degree Celcius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

36 2 Thermostat Control Resend Interval 0 to 32767
(Default)
Resend Interval in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

37 2 Thermostat Minimum On/Off Interval 60 to 32767
(Default)
Minimum On/Off interval in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

38 2 Thermostat Floor Temp Max 0 to 500
(Default)
Floor Temp Max in 1/10th of a degree Celcius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 2 Safety Activate Delay 0 to 32767
(Default)
Safety Activate Delay in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Temperature Sensor Select 1 to 3
(Default)
Temperature Sensor Select

Parameter Number

Parameter Size

Parameter Name

Parameter Values

44 1 Cold Start Minimum Level 1 to 99
(Default)
Cold Start Minimum Level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 Safety OFF Period 0 to 32767
(Default)
Safety OFF Period in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Safety ON Period 0 to 32767
(Default)
Safety ON Period in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

64 2 Temperature Report Inteval 0 to 32767
(Default)
Report Interval in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 1 Temperature Report Threshold 0 to 127
(Default)
Report Threshold in 1/10th of a degree Celcius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

67 1 Thermostat On∕Off Interval Override Threshold 0 to 127
(Default)
Temperature Threshold in 1/10th of a degree Celcius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 Button LED Mode 0 to 2
(Default)
Selected LED Mode