There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | First channel - operating mode | 0 (Default) |
standard operation | |
1 | delay ON function | ||||
2 | delay OFF function | ||||
3 | auto ON function | ||||
4 | auto OFF function | ||||
5 | flash function | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | First channel - reaction to switch for delay/auto ON/OFF modes | 0 (Default) |
cancel mode and set target state | |
1 | no reaction to switch - mode runs until it ends | ||||
2 | reset timer - start counting from the beginning | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | First channel - time parameter for delay/auto ON/OFF modes | 0 | 0.1s | |
1 to 32000 (Default) |
1-32000s, 1s step | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | First channel - pulse time for flashing mode | 1 to 32000 (Default) |
0.1-3200.0s, 0.1s step | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Second channel - operating mode | 0 (Default) |
standard operation | |
1 | delay ON function | ||||
2 | delay OFF function | ||||
3 | auto ON function | ||||
4 | auto OFF function | ||||
5 | flash function | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Second channel - reaction to switch for delay/auto ON/OFF modes | 0 (Default) |
cancel mode and set target state | |
1 | no reaction to switch - mode runs until it ends | ||||
2 | reset timer - start counting from the beginning | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 2 | Second channel - time parameter for delay/auto ON/OFF modes | 0 | 0.1s | |
1 to 32000 (Default) |
1-32000s, 1s step | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 2 | Second channel - pulse time for flashing mode | 1 to 32000 (Default) |
0.1-3200.0s, 0.1s step | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Switch type | 0 | momentary switch | |
1 | toggle switch (contact closed - ON, contact opened - OFF) | ||||
2 (Default) |
toggle switch (device changes status when switch changes status) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Flashing mode - reports | 0 (Default) |
the device does not send reports | |
1 | the device sends reports | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Associations in Z-Wave network security mode | 1 | 2nd group sent as secure | |
2 | 3rd group sent as secure | ||||
4 | 4th group sent as secure | ||||
8 | 5th group sent as secure | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
28 | 1 | S1 switch - scenes sent | 1 | Key pressed 1 time | |
2 | Key pressed 2 time | ||||
4 | Key pressed 3 time | ||||
8 | Key Hold Down and Key Released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
29 | 1 | S2 switch - scenes sent | 1 | Key pressed 1 time | |
2 | Key pressed 2 time | ||||
4 | Key pressed 3 time | ||||
8 | Key Hold Down and Key Released | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | S1 switch - associations sent to 2nd and 3rd association groups | 1 | ignore turning ON with 1 click of the switch | |
2 | ignore turning OFF with 1 click of the switch | ||||
4 | ignore holding and releasing the switch* | ||||
8 | ignore double click of the switch** | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
32 | 2 | S1 switch - Switch OFF value sent to 2nd and 3rd association groups | 0 (Default) |
turning off associated devices | |
1 to 99 | forcing level of associated devices | ||||
255 | setting associated devices to the last remembered state or turning them on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 2 | S1 switch - Double Click value sent to 2nd and 3rd association groups | 0 to 255 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
35 | 1 | S2 switch - associations sent to 2nd and 3rd association groups | 1 | NOTE Parameter 35 values may be combined, e.g. 1+2=3 means that associations for turning ON and OFF are not sent. | |
2 | ignore turning off with 1 click of the switch | ||||
4 | ignore holding and releasing the switch* | ||||
8 | ignore double click of the switch** | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
36 | 2 | S2 switch - Switch ON value sent to 2nd and 3rd association groups | 0 | turning off associated devices | |
1 to 99 | forcing level of associated devices | ||||
255 (Default) |
setting associated devices to the last remembered state or turning them on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
37 | 2 | S2 switch - Switch OFF value sent to 2nd and 3rd association groups | 0 (Default) |
turning off associated devices | |
1 to 99 | forcing level of associated devices | ||||
255 | setting associated devices to the last remembered state or turning them on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
38 | 2 | S2 switch - Double Click value sent to 2nd and 3rd association groups | 0 | turning off associated devices | |
1 to 99 (Default) |
forcing level of associated devices | ||||
255 | setting associated devices to the last remembered state or turning them on | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Reaction to General Alarm | 0 | alarm frame is ignored | |
1 | turn ON after receiving the alarm frame | ||||
2 | turn OFF after receiving the alarm frame | ||||
3 (Default) |
flash after receiving the alarm frame | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | Reaction to Flood Alarm | 0 | alarm frame is ignored | |
1 | alarm frame is ignored | ||||
2 (Default) |
turn OFF after receiving the alarm frame | ||||
3 | flash after receiving the alarm frame | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 1 | Reaction to CO/CO2/Smoke Alarm | 0 | alarm frame is ignored | |
1 | turn ON after receiving the alarm frame | ||||
2 | turn OFF after receiving the alarm frame | ||||
3 (Default) |
flash after receiving the alarm frame | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
43 | 1 | Reaction to Heat Alarm | 0 | alarm frame is ignored | |
1 (Default) |
turn ON after receiving the alarm frame | ||||
2 | turn OFF after receiving the alarm frame | ||||
3 | flash after receiving the alarm frame | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
44 | 2 | Flashing alarm duration | 1 to 32000 (Default) |
1-32000s, 1s step | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 1 | First channel - power reports | 0 | reports are disabled | |
1 to 100 (Default) |
(1-100%) - change in power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
51 | 1 | First channel - minimal time between power reports | 0 | periodic reports are disabled | |
1 to 120 (Default) |
(1-120s) - report interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
53 | 2 | First channel - energy reports | 0 | reports are disabled | |
1 to 32000 (Default) |
1-32000 (1-32000Wh) - change in energy | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
54 | 1 | Second channel - power reports | 0 to 255 (Default) |
||
0 | reports are disabled | ||||
1 to 100 (Default) |
(1-100%) - change in power | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
55 | 1 | Second channel - minimal time between power reports | 0 | periodic reports are disabled | |
1 to 120 (Default) |
(1-120s) - report interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
57 | 2 | Second channel - energy reports | 0 | reports are disabled | |
1 to 32000 (Default) |
1-32000 (1-32000Wh) - change in energy | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
58 | 2 | Periodic power reports | 0 | periodic reports are disabled | |
1 to 32000 (Default) |
(1-32000s) - report interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
59 | 2 | Periodic energy reports | 0 | periodic reports are disabled | |
1 to 32000 (Default) |
(1-32000s) - report interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Measuring energy consumed by the device itself | 0 (Default) |
function inactive | |
1 | function activate | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Restore state after power failure | 0 | the device does not save the state prior to the power failure and returns to „off” position | |
1 (Default) |
the device restores its state prior to the power failure | ||||