Z-Wave Products

There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: FIBARO Motion Sensor (FGMS-001)

Z-Wave Certification Number: ZC10-18015922


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 Motion detection - sensitivity 8 to 255
(Default)
sensitivity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 BASIC command class configuration 0
(Default)
BASIC ON and OFF command frames sent in Basic Command Class
  1 only the BASIC ON command frame sent in Basic Command Class
  2 only the BASIC OFF command frame sent in Basic Command Class

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 BASIC ON command frame value 0 to 255
(Default)
BASIC ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 BASIC OFF command frame value 0 to 255
(Default)
BASIC OFF

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Associations in Z-Wave network Security Mode 0 to 15
(Default)
group sent as secure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Motion detection - blind time 0 to 15
(Default)
(0.5-8 seconds, time [s] = 0.5 x (value+1))

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Tamper - sensitivity 0 tamper inactive
  1 to 121
(Default)
(0.08-2g; every 0.016g)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 2 Tamper - alarm cancellation delay 1 to 32767
(Default)
in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Tamper - operating modes 0
(Default)
tamper only
  1 tamper and earthquake detector
  2 tamper and orientation in space

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 Tamper - alarm cancellation 0 do not send tamper cancellation report
  1
(Default)
send tamper cancellation report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

28 1 Tamper - broadcast mode 0
(Default)
tamper alarm sent to 3rd association group
  1 tamper alarm sent in broadcast mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

29 1 Tamper - backward compatible broadcast mode 0
(Default)
backward compatible tamper alarm sent to 5th association group
  1 backward compatible tamper alarm sent in broadcast mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Motion detection - pulse counter 0 1 pulse
  1
(Default)
2 pulse
  2 3 pulse
  3 4 pulse

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Motion detection - window time 0 4 seconds
  1 8 seconds
  2
(Default)
12 seconds
  3 16 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 2 Illuminance report - threshold 0 reports are not sent
  1 to 32767
(Default)
(illuminance in lux)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Illuminance report - interval 0 periodical reports are not sent
  1 to 32767
(Default)
(in seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Motion detection - alarm cancellation delay 1 to 32767
(Default)
in seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 2 Temperature report - threshold 0 reports are not sent
  1 to 255
(Default)
(0.1-25.5°C, 0.1°C step)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 2 Temperature measuring - interval 0 temperature is not measured
  1 to 32767
(Default)
(in seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

64 2 Temperature report - interval 0
(Default)
periodical reports are not sent
  1 to 32767 (in seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Temperature offset -1000 to 1000
(Default)
(-100 - 100°C, 0.1°C, step)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Motion detection - operating mode 0
(Default)
PIR sensor always active
  1 PIR sensor active during the day only
  2 PIR sensor active during the night only

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 Visual LED indicator - signalling mode 0 LED inactive
  1 to 9 single long blink at the moment of reporting motion. No other motion will be indicated until alarm is cancelled.
  10 to 18
(Default)
single long blink at the moment of reporting motion and one short blink each time the motion is detected again.
  19 to 26 single long blink at the moment of reporting motion and two short blinks each time the motion is detected again.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

81 1 Visual LED indicator - brightness 0 brightness determined by the illuminance(parameters 82 and 83)
  1 to 100
(Default)
(1-100%)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

82 2 Visual LED indicator - illuminance for low indicator brightness 0 to 32767
(Default)
(in lux)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

83 2 Visual LED indicator - illuminance for high indicator brightness 0 to 32767
(Default)
(in lux)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

86 2 Visual LED indicator - temperature for blue colour 0 to 255
(Default)
(in Celsius degree)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

87 2 Visual LED indicator - temperature for red colour 0 to 255
(Default)
(in Celsius degree)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

89 1 Visual LED indicator - tamper alarm 0 tamper alarm is not indicated
  1
(Default)
tamper alarm is indicated

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 2 Motion detection - night/day 1 to 32767
(Default)