Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Flush 1 Relay (ZMNHAD1)

Z-Wave Certification Number: ZC10-18015974


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 In-wall Switch Type for Load 1 (Q⬆) to control I1 0 - push-button (momentary)
  1
(Default)
- on/off toggle switch

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Activate / deactivate ALL ON / ALL OFF Functionality 255
(Default)
- ALL ON active, ALL OFF active
  0 - ALL ON not active, ALL OFF not active
  1 - ALL ON not active, ALL OFF active
  2 - ALL ON active, ALL OFF not active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 – Enable / Disable Endpoint I2 or select the Notification Type and the Notification Event 1 - Home Security; Motion Detection, unknown location
  2 - CO; Carbon Monoxide detected, unknown location
  3 - CO2; Carbon Dioxide detected, unknown location
  4 - Water Alarm; Water Leak detected, unknown location
  5 - Heat Alarm; Overheat detected, unknown location
  6 - Smoke Alarm; Smoke detected, unknown location
  0
(Default)
- Endpoint, I2 disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 1 Enable / Disable Endpoint I3 or select the Notification Type and the Notification Event 0
(Default)
- Endpoint, I2 disabled
  1 - Home Security; Motion Detection, unknown location
  2 - CO; Carbon Monoxide detected, unknown location
  3 - CO2; Carbon Dioxide detected, unknown location
  4 - Water Alarm; Water Leak detected, unknown location
  5 - Heat Alarm; Overheat detected, unknown location
  6 - Smoke Alarm; Smoke detected, unknown location

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Turn Load 1 (Q⬆) Off Automatically with Timer 0
(Default)
- Auto OFF Disabled
  1 to 32535 = 1 - 32535 seconds (or milliseconds – see Parameter no. 15) Auto OFF timer enabled for a given amount of seconds (or milliseconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 2 Temperature Sensor Offset Settings 32536
(Default)
- Offset is 0 degrees Celsius
  1 to 100 - Where 1 stands for 0.1 and 100 stands for 10.00 degrees Celsius added to the actual measurement
  1001 to 1100 – Where 1001 stands for -0.1 degrees Celsius and 1100 stands for -10.0 degrees Celsius subtracted from the actual measurement

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Turn Load 1 (Q⬆) On Automatically with Timer 0
(Default)
- Auto ON Disabled
  1 to 32535 = 1 - 32536 seconds (or milliseconds – see Parameter no. 15) Auto ON timer enabled- for a given amount of seconds (or milliseconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Temperature Sensor Reporting Threshold If 5
(Default)
- 0.5 Degrees Celsius
  0 - Reporting disabled
  1 to 127
(Default)
Where 1 stands for 0.1 degrees Celsius and 127 stands for 12.7 degrees Celsius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Set Timer Units to Seconds or Milliseconds 0
(Default)
– timer set in seconds
  1 – timer set in milliseconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Input 2 contact type 0
(Default)
- NO (normally open) input type
  1 - NC (normally close) input type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Input 3 contact type 0
(Default)
- NO (normally open) input type
  1 - NC (normally close) input type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Restore on/off status for Q⬆ load after power failure 0
(Default)
- Device saves last on/off status and restores it after a power failure.
  1 - Device does not save on/off status and does not restore it after a power failure, it remains off.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Watt Power Consumption Reporting Threshold for Q⬆ Load 0 - Power consumption reporting disabled
  1 to 100
(Default)
= 1% - 100% Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Watt Power Consumption Reporting Time Threshold for Q⬆ Load 0
(Default)
- Power consumption reporting disabled
  1 to 32535 = 1 - 32535 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

63 1 Choose Normally Closed or Normally Open for Q⬆ Load 0
(Default)
- When switch/device is off the output is 0V (NC).
  1 - When switch/device is off the output is 230V or 24VDC (NO).