TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | In-wall Switch Type for Load 1 (Q⬆) to control I1 | 0 | - push-button (momentary) | |
1 (Default) |
- on/off toggle switch | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Activate / deactivate ALL ON / ALL OFF Functionality | 255 (Default) |
- ALL ON active, ALL OFF active | |
0 | - ALL ON not active, ALL OFF not active | ||||
1 | - ALL ON not active, ALL OFF active | ||||
2 | - ALL ON active, ALL OFF not active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
100 | 1 | – Enable / Disable Endpoint I2 or select the Notification Type and the Notification Event | 1 | - Home Security; Motion Detection, unknown location | |
2 | - CO; Carbon Monoxide detected, unknown location | ||||
3 | - CO2; Carbon Dioxide detected, unknown location | ||||
4 | - Water Alarm; Water Leak detected, unknown location | ||||
5 | - Heat Alarm; Overheat detected, unknown location | ||||
6 | - Smoke Alarm; Smoke detected, unknown location | ||||
0 (Default) |
- Endpoint, I2 disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 1 | Enable / Disable Endpoint I3 or select the Notification Type and the Notification Event | 0 (Default) |
- Endpoint, I2 disabled | |
1 | - Home Security; Motion Detection, unknown location | ||||
2 | - CO; Carbon Monoxide detected, unknown location | ||||
3 | - CO2; Carbon Dioxide detected, unknown location | ||||
4 | - Water Alarm; Water Leak detected, unknown location | ||||
5 | - Heat Alarm; Overheat detected, unknown location | ||||
6 | - Smoke Alarm; Smoke detected, unknown location | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Turn Load 1 (Q⬆) Off Automatically with Timer | 0 (Default) |
- Auto OFF Disabled | |
1 to 32535 | = 1 - 32535 seconds (or milliseconds – see Parameter no. 15) Auto OFF timer enabled for a given amount of seconds (or milliseconds) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 2 | Temperature Sensor Offset Settings | 32536 (Default) |
- Offset is 0 degrees Celsius | |
1 to 100 | - Where 1 stands for 0.1 and 100 stands for 10.00 degrees Celsius added to the actual measurement | ||||
1001 to 1100 | – Where 1001 stands for -0.1 degrees Celsius and 1100 stands for -10.0 degrees Celsius subtracted from the actual measurement | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Turn Load 1 (Q⬆) On Automatically with Timer | 0 (Default) |
- Auto ON Disabled | |
1 to 32535 | = 1 - 32536 seconds (or milliseconds – see Parameter no. 15) Auto ON timer enabled- for a given amount of seconds (or milliseconds) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
120 | 1 | Temperature Sensor Reporting Threshold If | 5 (Default) |
- 0.5 Degrees Celsius | |
0 | - Reporting disabled | ||||
1 to 127 (Default) |
Where 1 stands for 0.1 degrees Celsius and 127 stands for 12.7 degrees Celsius | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Set Timer Units to Seconds or Milliseconds | 0 (Default) |
– timer set in seconds | |
1 | – timer set in milliseconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Input 2 contact type | 0 (Default) |
- NO (normally open) input type | |
1 | - NC (normally close) input type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Input 3 contact type | 0 (Default) |
- NO (normally open) input type | |
1 | - NC (normally close) input type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Restore on/off status for Q⬆ load after power failure | 0 (Default) |
- Device saves last on/off status and restores it after a power failure. | |
1 | - Device does not save on/off status and does not restore it after a power failure, it remains off. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Watt Power Consumption Reporting Threshold for Q⬆ Load | 0 | - Power consumption reporting disabled | |
1 to 100 (Default) |
= 1% - 100% Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 2 | Watt Power Consumption Reporting Time Threshold for Q⬆ Load | 0 (Default) |
- Power consumption reporting disabled | |
1 to 32535 | = 1 - 32535 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 1 | Choose Normally Closed or Normally Open for Q⬆ Load | 0 (Default) |
- When switch/device is off the output is 0V (NC). | |
1 | - When switch/device is off the output is 230V or 24VDC (NO). | ||||