There are over 4409 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
100 | 1 | Set the parameter 101-103 to default values. | 1 | Set the parameter 101-103 to default values. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | To set which report would be sent in Report group 1 | 1 | Battery Report is enabled. | |
16 | Ultraviolet Report is enabled. | ||||
32 | Temperature Report is enabled. | ||||
64 | Humidity Report is enabled. | ||||
128 | Luminance Report is enabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | To set which report would be sent in Report group 2 | 1 | Battery Report is enabled. | |
16 | Ultraviolet Report is enabled. | ||||
32 | Temperature Report is enabled. | ||||
64 | Humidity Report is enabled. | ||||
128 | Luminance Report is enabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | To set which report would be sent in Report group 3 | 1 | Battery Report is enabled. | |
16 | Ultraviolet Report is enabled. | ||||
32 | Temperature Report is enabled. | ||||
64 | Humidity Report is enabled. | ||||
128 | Luminance Report is enabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | To set the interval time of sending reports in Report group 1 | 5 to 2678400 (Default) |
Available range is 5 to 2678400 seconds. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | To set the interval time of sending reports in Report group 2 | 5 to 2678400 (Default) |
Available range is 5 to 2678400 seconds. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | To set the interval time of sending reports in Report group 3 | 5 to 2678400 (Default) |
Available range is 5 to 2678400 seconds. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. | 0 (Default) |
Disable | |
1 | Enable. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
201 | 2 | Temperature sensor calibration | -128 to 127 (Default) |
Available range is -12.8℃ to 12.7℃. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
202 | 1 | Humidity sensor calibration | -50 to 50 (Default) |
Available range is -50RH to 50RH. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
203 | 2 | Luminance sensor calibration | -1000 to 1000 (Default) |
Available range is -1000Lux to 1000Lux. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
204 | 1 | Ultraviolet sensor calibration | -10 to 10 (Default) |
Available range is -10 to 10. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/disable all configuration parameters to be locked | 0 (Default) |
Disable | |
1 | Enable. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset to factory defaults. | 1 | Reset all configuration parameters to factory defaults. | |
1431655765 | Reset the product to factory defaults. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 2 | Set the PIR time. | 10 to 3600 (Default) |
The range of PIR time is 10 to 3600. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
39 | 1 | Configure the default low battery value. | 10 to 50 (Default) |
Available range is 10% to 50%. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Set the sensitivity of the motion sensor. | 0 | Minimum Sensitivity | |
1 | Sensitivity Level 1 of 6 | ||||
2 | Sensitivity Level 2 of 6 | ||||
3 | Sensitivity Level 3 of 6 | ||||
4 | Sensitivity Level 5 of 6 | ||||
5 (Default) |
Maximum Sensitivity | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Enable/disable the selective reporting only when measurements reach a certain threshold or percentage | 0 (Default) |
Disable | |
1 | Enable. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 4 | Threshold change in temperature to induce an automatic report. | 10 to 2120 (Default) |
Available range of threshold is 1℉ to 212℉. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 1 | Threshold change in humidity to induce an automatic report | 1 to 100 (Default) |
Available range is 1% to 100%. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
43 | 2 | Threshold change in luminance to induce an automatic report. | 1 to 30000 (Default) |
Available range is 1 LUX to 30000 LUX. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
44 | 1 | Threshold change in battery level to induce an automatic report. | 1 to 100 (Default) |
Available range is 1% to 100%. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
45 | 1 | Threshold change in ultraviolet to induce an automatic report. | 1 to 11 (Default) |
Available range is 1 to 11. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
46 | 1 | Enable/disable to send the alarm report of low temperature | 0 (Default) |
Disable | |
1 | Enable. | ||||
1 to 30000 | Available range is 1LUX to 30000LUX. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
48 | 1 | Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. | 0 (Default) |
Disable | |
1 | Enable. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
49 | 4 | Set the upper limit value of temperature sensor. | -400 to 2120 (Default) |
Available range is -40.0℉ to 212.0℉. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Which command would be sent when the motion sensor triggered. | 1 (Default) |
Send Basic Set CC | |
2 | Send Sensor Binary Report CC | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 4 | Set the lower limit value of temperature sensor. | -400 to 2120 (Default) |
Available range is -40.0℉ to 212.0℉. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
51 | 1 | Set the upper limit value of humidity sensor. | 0 to 100 (Default) |
Available range is 0% to 100%. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
52 | 1 | Set the lower limit value of humidity sensor. | 0 to 100 (Default) |
Available range is 0% to 100%. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
53 | 1 | Set the upper limit value of Lighting sensor | 0 to 30000 (Default) |
Available range is 0 to 30000LUX. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
54 | 1 | Set the lower limit value of Lighting sensor. | 0 to 30000 (Default) |
Available range is 0 to 30000LUX. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
55 | 1 | Set the upper limit value of ultraviolet sensor. | 1 to 11 (Default) |
Available range is 1 to 11. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
56 | 1 | Set the lower limit value of ultraviolet sensor. | 1 to 11 (Default) |
Available range is 1 to 11. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
57 | 2 | Set the recover limit value of temperature sensor. | 10 to 255 (Default) |
Available range is 1.0℉ to 25.5℉ | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
58 | 1 | Set the recover limit value of humidity sensor. | 1 to 50 (Default) |
Available range is 1 to 50% | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
59 | 1 | Set the recover limit value of Lighting sensor. | 1 to 127 (Default) |
Available range is 10Lux to 1270Lux | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Set the recover limit value of Ultraviolet sensor. | 0 | USB power mode | |
1 to 5 (Default) |
Available range is 1 to 5. | ||||
256 | Keep sleep state for Battery power mode | ||||
257 | Keep awake for 10 minutes for battery power mode. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 2 | Get the out-of-limit state of the Sensors. | 1 | Temperature sensor is out of the lower limit | |
2 | Humidity sensor is out of the lower limit | ||||
4 | Luminance sensor is out of the lower limit | ||||
8 | Ultraviolet sensor is out of the lower limit | ||||
16 | Temperature sensor is out of the upper limit | ||||
32 | Humidity sensor is out of the upper limit | ||||
64 | Luminance sensor is out of the upper limit | ||||
128 | Ultraviolet sensor is out of the upper limit | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
64 | 1 | Set the default unit of the automatic temperature report in parameter 101-103. | 1 | The unit is Celsius. | |
2 (Default) |
The unit is Fahrenheit. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Set the timeout of awake after the Wake Up CC is sent out.. | 8 to 127 (Default) |
Available range is 8 to 127 seconds. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
81 | 1 | Enable/disable the LED blinking when the PIR is triggered. | 0 (Default) |
Enable. | |
1 | Disable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | Report the current power mode and the product state for battery power mode | 0 (Default) |
USB power mode | |
256 | Keep sleep state for Battery power mode | ||||
257 | Keep awake for 10 minutes for battery power mode. | ||||