There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Basic Set OFF Level | -128 to 127 (Default) |
Setting the BASIC command value. When the flood trigger off(0x00), send the BASIC CC to the group 2. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Auto Report Battery Time | 0 to 127 (Default) |
The interval time for auto report the battery level. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Auto Report Temperatur e Time | 0 to 127 (Default) |
The interval time for auto report the temperature. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Auto Report Humidity Time | 0 to 127 (Default) |
The interval time for auto report the humidity. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Auto Report Flood Time | 0 to 127 (Default) |
The interval time for auto report the flood state. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Basic Set ON Level | -128 to 127 (Default) |
Setting the BASIC command value. When the flood trigger on(0xFF), send the BASIC CC to the group 2. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Auto Report Tick Interval | -128 to 127 (Default) |
The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15. Units of one minute. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Temperature Differential Report | 0 to 127 (Default) |
The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every 10 seconds. And when the temperature is over 140 degree Fahrenheit, it will continue report. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Humidity Differential Report | 0 to 60 (Default) |
The humidity differential to report. 0 means turn off this function. The unit is percentage. Enable this function the device will detect every 10 seconds. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Operation Mode | 0 (Default) |
Bit0: Disable the Flood function. | |
3 | Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius | ||||
5 | Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Mult- Sensor Function Switch | 6 | Bit6: Disable the humidity report after event triggered. (1:Disable, 0:Enable) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Customer Function | 3 | Bit3: Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable) | |
4 | Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. | ||||
5 | Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable) | ||||
6 | Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) | ||||