Z-Wave Products

There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Flood Multisensor (PAT02-1A)

Z-Wave Certification Number: ZC10-18036035


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Basic Set OFF Level -128 to 127
(Default)
Setting the BASIC command value. When the flood trigger off(0x00), send the BASIC CC to the group 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Auto Report Battery Time 0 to 127
(Default)
The interval time for auto report the battery level. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Auto Report Temperatur e Time 0 to 127
(Default)
The interval time for auto report the temperature. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Auto Report Humidity Time 0 to 127
(Default)
The interval time for auto report the humidity. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Auto Report Flood Time 0 to 127
(Default)
The interval time for auto report the flood state. 0 means turn off auto report. The default value is 12. The tick time can setting by the configuration No.20.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Basic Set ON Level -128 to 127
(Default)
Setting the BASIC command value. When the flood trigger on(0xFF), send the BASIC CC to the group 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Auto Report Tick Interval -128 to 127
(Default)
The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15. Units of one minute.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Temperature Differential Report 0 to 127
(Default)
The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every 10 seconds. And when the temperature is over 140 degree Fahrenheit, it will continue report.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Humidity Differential Report 0 to 60
(Default)
The humidity differential to report. 0 means turn off this function. The unit is percentage. Enable this function the device will detect every 10 seconds.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Operation Mode 0
(Default)
Bit0: Disable the Flood function.
  3 Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius
  5 Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Mult- Sensor Function Switch 6 Bit6: Disable the humidity report after event triggered. (1:Disable, 0:Enable)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Customer Function 3 Bit3: Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable)
  4 Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
  5 Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable)
  6 Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable)