TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: FIBARO Smoke Sensor (FGSD-002)

Z-Wave Certification Number: ZC10-18025999


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Fibaro Smoke Sensor sensitivity 1 HIGH Sensitivity
  2
(Default)
MEDIUM Sensitivity
  3 LOW Sensitivity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Configuration of control frames in BASIC command class 0
(Default)
BASIC ON & BASIC OFF enabled
  1 BASIC ON enabled
  2 BASIC OFF enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 BASIC ON frame value 0 turn off the device
  1 to 99 set the device to 1-99%
  255
(Default)
set the last status

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 BASIC OFF frame value 0
(Default)
turn off the device
  1 to 99 set the device to 1-99%
  255 set the last status

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Alarm broadcast 0
(Default)
broadcast inactive
  1 SMOKE ALARM command broadcast (2-nd & 4-th Association Group) active; casing opening notification broadcast (3-rd & 5-th Association Group) inactive
  2 SMOKE ALARM command broadcast (2-nd & 4-th Association Group) inactive; casing opening notification broadcast (3-rd & 5-th Association Group) active
  3 SMOKE ALARM command broadcast (2-nd & 4-th Association Group) active; casing opening notification broadcast (3-rd & 5-th Association Group) active.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Associations in Z-Wave network security mode 0 all groups sent as non-secure
  1 2nd group sent as secure
  2 3rd group sent as secure
  4 4th group sent as secure
  8 5th group sent as secure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Z-Wave notifications status 0
(Default)
all notifications disabled
  1 casing opening notification enabled
  2 exceeding temperature threshold notification enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 2 Temperature report interval 0 reports inactive
  1 to 8640
(Default)
[10s-24h]

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Temperature report hysteresis 1 to 100
(Default)
(multiply by 0.1)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Visual indicator notifications status 0
(Default)
all notifications disabled
  1 casing opening notification enabled
  2 exceeding temperature threshold notification enabled
  4 lack of Z-Wave range notification

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Temperature threshold 1 to 100
(Default)
1°C-100°C

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 2 Excess temperature signaling interval 1 to 8640
(Default)
[10s-24h]

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 2 Lack of Z-Wave range indication interval 1 to 8640
(Default)
[10s-24h]

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Sound notifications status 0
(Default)
all notifications disabled
  1 casing opening notification enabled
  2 exceeding temperature threshold notification enabled
  4 lack of Z-Wave range notification