Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Input 1 switch type | 0 (Default) |
mono-stable switch type (push button) – button quick press turns between previous set Dimmer value and zero | |
1 | bi-stable switch type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Activate / deactivate functions ALL ON / ALL OFF | 0 | ALL ON is not active, ALL OFF is not active | |
1 | ALL ON is not active, ALL OFF active | ||||
2 | ALL ON active, ALL OFF is not active | ||||
255 (Default) |
ALL ON active, ALL OFF active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
100 | 1 | Enable / Disable Endpoints I2 or select | 0 (Default) |
Endpoint, I2 disabled | |
0 (Default) |
|||||
1 | Home Security; Motion Detection, unknown loc. | ||||
2 | CO; Carbon Monoxide detected, unknown loc. | ||||
3 | CO2; Carbon Dioxide detected, unknown loc. | ||||
4 | Water Alarm; Water Leak detected, unknown loc. | ||||
5 | Heat Alarm; Overheat detected, unknown loc. | ||||
6 | Smoke Alarm; Smoke detected, unknown loc. | ||||
9 | Sensor binary | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 1 | Enable / Disable Endpoints I3 or select Notification Type and Event | 0 (Default) |
Endpoint, I3 disabled - sensor binary (9): GENERIC_TYPE_SENSOR_BINARY, SPECIFIC_TYPE_NOT_USED | |
1 | Home Security; Motion Detection, unknown loc. | ||||
2 | CO; Carbon Monoxide detected, unknown loc. | ||||
3 | CO2; Carbon Dioxide detected, unknown loc. | ||||
4 | Water Alarm; Water Leak detected, unknown loc. | ||||
5 | Heat Alarm; Overheat detected, unknown loc. | ||||
6 | Smoke Alarm; Smoke detected, unknown loc. | ||||
9 | Sensor binary | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Automatic turning off output after set time | 0 (Default) |
Auto OFF disabled | |
1 to 32536 | = 1second - 32536 seconds Auto OFF enabled with define time, step is 1 second | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 2 | Temperature sensor offset settings | 1 to 100 | value from 0.1 degrees Celsius to 10.0 degrees Celsius is added to actual measured temperature | |
1001 to 1100 | value from -0.1 degrees Celsius to -10.0 degrees Celsius is subtracted to actual measured temperature. | ||||
32536 (Default) |
offset is 0.0C | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Automatic turning on output after set time | 0 (Default) |
Auto ON disabled | |
1 to 32535 | = 1second - 32535 seconds Auto ON enabled with define time, step is 1 second | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
120 | 1 | Temperature sensor reporting | 0 | reporting disabled | |
1 to 127 (Default) |
= 0,1 degrees Celsius - 12,7 degrees Celsius, step is 0,1 degrees Celsius | ||||
5 (Default) |
= 0,5 degrees Celsius change | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Input 2 switch type | 0 (Default) |
mono-stable switch type (push button) – button quick press turns between previous set Dimmer value and zero | |
1 | bi-stable switch type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Enable/Disable 3way switch/ additional switch | 0 (Default) |
single push button (connected to I1) | |
1 | 3 way switch (connected to I1 and I2) | ||||
2 | additional switch (connected to I2) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | nable/Disable Double click function | 0 (Default) |
double click disabled | |
1 | double click enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
249 | 1 | Enable/Disable Reporting on Set command | 0 | Disable reporting | |
1 (Default) |
Enable reporting | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
250 | 1 | Unsecure / Secure Inclusion | 0 (Default) |
Unsecure Inclusion | |
1 | Secure Inclusion | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Input 2 contact type | 0 (Default) |
NO (normally open) input type | |
1 | NC (normally close) input type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Saving the state of the device after a power failure | 0 (Default) |
Flush Dimmer module saves its state before power failure (it returns to the last position saved before a power failure) | |
1 | Flush Dimmer module does not save the state after a power failure, it returns to "off" position | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Input 3 contact type | 0 (Default) |
NO (normally open) input type | |
1 | NC (normally close) input type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Power reporting in Watts on power change | 0 | reporting disabled | |
1 to 100 (Default) |
= 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1% | ||||
5 (Default) |
default value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 2 | Power reporting in Watts by time interval | 0 (Default) |
reporting disabled | |
1 to 32767 | = 1 second - 32767 seconds. Reporting enabled. Power report is send with time interval set by entered value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Minimum dimming value | 1 (Default) |
= 1% (minimum dimming value) | |
1 to 98 (Default) |
= 1% - 98%, step is 1%. Minimum dimming values is set by entered value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 1 | Maximum dimming value | 2 to 99 (Default) |
= 2% - 99%, step is 1%. Maximum dimming values is set by entered value | |
99 (Default) |
= 99% (Maximum dimming value) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 2 | Dimming time (soft on/off) | 50 to 255 (Default) |
= 500 mseconds - 2550 mseconds (2,55s), step is 10 mseconds | |
100 (Default) |
= 1s | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 2 | Dimming time when key pressed | 1 to 255 (Default) |
= 1 second – 255 seconds | |
3 (Default) |
= 3s | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
67 | 1 | Ignore start level | 0 (Default) |
respect start level | |
1 | ignore start level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
68 | 1 | Dimming duration | 0 (Default) |
dimming duration according to parameter 66 | |
1 to 127 | from 1 to 127 seconds | ||||