Z-Wave Products

There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Z-Wave Metering Plug Smart Start (POPE700397)

Z-Wave Certification Number: ZC10-18026015


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 LED Operation Mode 0 LED off, only blinks on traffic
  1
(Default)
Defined by Parameter 21 and 22

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 2 Auto-off 0
(Default)
no auto-off
  1 to 65535 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 LED Color on OFF state 0
(Default)
Off
  1 Red
  2 Green

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 LED Color on ON state 0 Off
  1 Red
  2
(Default)
Green

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Voltage Report Threshold 0 Disabled
  1 to 250
(Default)
Volt

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Current Reporting Threshold 0 Disabled
  1 to 255
(Default)
* 0,01 A

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 Power Reporting Threshold 0 Disabled
  1 to 255
(Default)
W

Parameter Number

Parameter Size

Parameter Name

Parameter Values

26 2 Soft Circuit Breaker Threshold 0 Disabled
  1 to 3600
(Default)
W

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Soft Circuit Breaker Recovery Time 0
(Default)
Never
  1 to 255 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

28 1 Soft Circuit Breaker Delay Time 0 to 255
(Default)
* 0,1 sec

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Switching behavior when receiving wireless OFF 0
(Default)
Switches off
  1 Ignores Off command
  2 Switches on
  3 Switches on, when receiving off command and current state is off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Button Mode 0
(Default)
Controls Load + Controls Scenes
  1 Scene Control Only

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Status after Power Failure 0 Always off
  1
(Default)
Return to last switching state