There are over 4409 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Association LED | 0 (Default) |
Turns off the center LED | |
1 to 255 | Turn on the center LED | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Delay ON | 0 (Default) |
Disables timing | |
1 to 127 | Sets a timing with a range of (1-127sec) | ||||
128 to 254 | Sets a timing with range of (1-127min) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Activation Time | 0 (Default) |
Disables timing | |
128 to 254 | Sets a timing with range of (1-127min) | ||||
1 to 127 | Sets a timing with range of (1-127sec) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Behavior of LED in Repose | 0 | LED1 remains OFF and only informs of load state during 5 sec. after pressing the button. | |
1 to 255 (Default) |
LED1 always shows the load state | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Lock Input | 0 (Default) |
Enables the pushbutton to control the load | |
1 to 255 | Disables the action of the pushbutton on the load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Reset Default | 39015 | Performs a Reset devault | |
17170 | Performs configuration default values process | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Delay OFF | 0 (Default) |
Disables timing | |
1 to 127 | Sets a timing with range of (1-127sec) | ||||
128 to 254 | Sets a timing with range of (1-127min) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | PostReset State | 0 | After a reset the load starts Off | |
1 to 255 (Default) |
After a reset the load recovers the last value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Pulse Action | 0 (Default) |
TOGGLE, A short press switches the | |
1 | ON. A short press activates the load | ||||
2 | OFF. A short press deactivates the load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | Custom consumption limit | 0 (Default) |
Disables custom consumption limit | |
1 to 3680 | Sets the power in Watts that is supported (once the load is over, it is disconnected). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Identify | 255 | The central LED flashes for 5 seconds at a frequency of 0.1s | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 2 | Loas State | 0 (Default) |
Load is OFF | |
511 | Load is ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Lock Hold Press | 0 (Default) |
Hold press works as expected | |
1 to 255 | Blocks HOLD press actions from 2 to 30s and hold press of 30s sets de HUb in learning proces but not resets it. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Beacon | 0 (Default) |
Disables the beacon function. | |
1 to 99 | Sets the intensity of the beacon LEDs. | ||||