There are over 4387 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Датчик движения (Motion Sensor) (PST02-5B)

Z-Wave Certification Number: ZC10-18026029


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Auto Report Battery Time 0 to 127
(Default)
The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Auto Report Illumination Time 0 to 127
(Default)
The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Auto Report Temperature Time 0 to 127
(Default)
The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Basic Set Level -128 to 127
(Default)
Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Auto Report Tick Interval -128 to 127
(Default)
The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. The unit is 1 minute.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Temperature Differential Report 0 to 127
(Default)
The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device willdetect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the “Temperature Report” section.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Illumination Differential Report 0 to 99
(Default)
The illumination differential to report. 0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the “Illumination Report” section.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 PIR Sensitivity 0 to 99
(Default)
PIR sensitivity settings. 0 means disable the PIR motion. 1 means the lowest sensitivity, 99 means the highest sensitivity. High sensitivity means can detected long distance, but if there is more noise signal in the environment, it will re-trigger too frequency.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Light Threshold 0 to 100
(Default)
0 means turn off illumination detected function. And never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Operation Mode 1 1 means test mode, 0 means normal mode.
  3 Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius
  4 Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable)
  5 Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)
  7 Bit7: Disable the back key release into test mode. (1:Disable, 0:Enable)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Mult- Sensor Function Switch 2 Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Customer Function 1 Bit1: Enable sending motion OFF report. (0:Disable, 1:Enable)
  2 Bit2: Enable PIR super sensitivity mode. (0:Disable, 1:Enable)
  4
(Default)
Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
  5 Bit5: Disable Multi CC in auto report.(1:Disable, 0:Enable)
  6 Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 PIR Re- Detect Interval Time 1 to 127
(Default)
In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Turn Off Light Time 0 to 127
(Default)
After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command