TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Mode Control | The awning blind mode operate: 0 – manual - control with the use of the remote control 1 – semiautomatic - automatic closing and with the use of the remote control 2 – automatic -automatic opening and closing and with the use of the remote control | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 2 | No | No | Yes |
From |
To |
Description |
|||
0 | 2 | 0 - manual, 1 – semiautomatic, 2 – automatic | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 1 | Calibrate | Value 1 – calibrated Value 2 – discalibrated – to enter the calibration mode must first time discalibrate and then calibrate. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 2 | No | No | No |
From |
To |
Description |
|||
1 | 2 | 1-calibrate, 2-discalibrate | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | The End position | 1 – FF go to maximum position 2 – FF go to previous position | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 2 | No | No | No |
From |
To |
Description |
|||
1 | 2 | 1 – FF is maximum position, 2 – FF is previous position | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Season select | Season of using awning blind 1 – summer 2 – winter | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 2 | No | No | No |
From |
To |
Description |
|||
1 | 2 | 1 – summer, 2 – winter | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Timer | The time after which the awning blind will be open or close (depend on the season) | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 1 | 30 | No | No | No |
From |
To |
Description |
|||
1 | 30 | 1 to 30 minutes | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Sensitivity | Level of sun sensitivity at which the awning blind will open or close. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 3 | 100 | No | No | No |
From |
To |
Description |
|||
3 | 100 | 3 to 100 procent | |||