Z-Wave Products

There are over 4395 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Plug-in Switch Mini ( TZWP-102)

Z-Wave Certification Number: ZC10-18036072


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Over current protection 0 The function is disabled
  1
(Default)
The function is enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Setting the parameters 101~104 to the default value. 85 Setting the parameters 101~104 to the default value.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 Setting time for sending meter report (watt) 0 The function is disabled.
  5 to 2678400
(Default)
Available settings

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 Setting time for sending meter report (KWh) 0 The function is disabled.
  5 to 2678400
(Default)
Available settings

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 Setting time for sending meter report (voltage) 0
(Default)
The function is disabled
  5 to 2678400 Available settings

Parameter Number

Parameter Size

Parameter Name

Parameter Values

104 4 Setting time for sending meter report (current) 0
(Default)
The function is disabled
  5 to 2678400 Available settings

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 The value here represents minimum change in wattage (in terms of wattage) for a meter report to be sent 0 The function is disabled.
  1 to 65535
(Default)
Available settings

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 The value here represents minimum change in wattage percent (in terms of percentage) for a meter report (watt) to be sent -128 to 127
(Default)
Available setting
  0 The function is disabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Setting device status after power failure 0
(Default)
Smart Plug memorizes its state after a power failure.
  1 Connected device will be on after the power supply is reconnected.
  2 Connected device will be off after the power supply is reconnected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

254 1 Enable/disable the configuration command 0
(Default)
Unlock
  1 Lock

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Notification when Load status change 0 The function is disabled.
  1
(Default)
Send Basic report.
  2 Send Basic report only when Load status is not changed by Z-WAVE Command.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 LED Load indicator mode selection 0
(Default)
The LED status follows the load change.
  1 when operating the load, The LED lights for 5 seconds and then turns off.