There are over 4395 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Over current protection | 0 | The function is disabled | |
1 (Default) |
The function is enabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
100 | 1 | Setting the parameters 101~104 to the default value. | 85 | Setting the parameters 101~104 to the default value. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | Setting time for sending meter report (watt) | 0 | The function is disabled. | |
5 to 2678400 (Default) |
Available settings | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | Setting time for sending meter report (KWh) | 0 | The function is disabled. | |
5 to 2678400 (Default) |
Available settings | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | Setting time for sending meter report (voltage) | 0 (Default) |
The function is disabled | |
5 to 2678400 | Available settings | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
104 | 4 | Setting time for sending meter report (current) | 0 (Default) |
The function is disabled | |
5 to 2678400 | Available settings | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 2 | The value here represents minimum change in wattage (in terms of wattage) for a meter report to be sent | 0 | The function is disabled. | |
1 to 65535 (Default) |
Available settings | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | The value here represents minimum change in wattage percent (in terms of percentage) for a meter report (watt) to be sent | -128 to 127 (Default) |
Available setting | |
0 | The function is disabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Setting device status after power failure | 0 (Default) |
Smart Plug memorizes its state after a power failure. | |
1 | Connected device will be on after the power supply is reconnected. | ||||
2 | Connected device will be off after the power supply is reconnected. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
254 | 1 | Enable/disable the configuration command | 0 (Default) |
Unlock | |
1 | Lock | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Notification when Load status change | 0 | The function is disabled. | |
1 (Default) |
Send Basic report. | ||||
2 | Send Basic report only when Load status is not changed by Z-WAVE Command. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | LED Load indicator mode selection | 0 (Default) |
The LED status follows the load change. | |
1 | when operating the load, The LED lights for 5 seconds and then turns off. | ||||