There are over 4296 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: HC Shutter FM (MT 02761)

Z-Wave Certification Number: ZC10-18076191


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Activate/deactivate functions ALL ON / ALL OFF 0 ALL ON is not active ALL OFF is not activ
  1 ALL ON is not active ALL OFF active
  2 ALL ON active ALL OFF is not active
  255
(Default)
ALL ON active, ALL OFF active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 2 Temperature sensor offset settings 1 to 100 Value from 0.1 Degrees Celsius to 10.0 Degrees Celsius is added to actual measured temperature
  1001 to 1100 Value from -0.1 Degrees Celsius to -10.0 Degrees Celsius is subtracted to actual measured temperature
  32536
(Default)
Offset is 0.0 Degrees Celsius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Temperature sensor reporting 0 Reporting disabled
  1 to 127
(Default)
= 0,1 Degrees Celsius - 12,7 Degees Celsius; step is 0,1 Degrees Celsius
  5
(Default)
= 0,5 Degrees Celsius

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Power reporting in Watts on power change for Q1 or Q2 0 Reporting disabled
  1 to 100
(Default)
= 1% - 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Power reporting in Watts by time interval for Q1 or Q2 0
(Default)
Reporting disabled
  1 to 32767 = 1 second - 32767 seconds. Reporting enabled, power report is send with time interval set by entered value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

71 1 Operating modes 0
(Default)
Shutter mode
  1 Venetian mode (up/down and slate rotation)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

72 2 Slats tilting full turn time 0 Tilting time disabled
  2 to 32767
(Default)
= 0,01seconds - 327,67 seconds
  150
(Default)
= 1,5 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

73 1 Slats position 0 Slats return to previously set position only in case of Z-wave control (not valid for limit switch positions)
  1
(Default)
Slats return to previously set position in case of Z-wave control, push-button operation or when the lower limit switch is reached

Parameter Number

Parameter Size

Parameter Name

Parameter Values

74 2 Motor moving up/down time 0
(Default)
Moving time disabled (working with limit switches)
  1 to 32767 = 0,1 seconds - 3276,7 seconds. After that time motor is stopped (relay goes to off state)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

76 1 Motor operation detection 0 to 127
(Default)
= 1-127 W. The value 0 means reaching a limit switch will not be detected

Parameter Number

Parameter Size

Parameter Name

Parameter Values

78 1 Forced Shutter calibration 0
(Default)
  1 Start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

85 1 – Power consumption max delay time 0 = time is set automatically
  3 to 50
(Default)
= 0,3seconds - 5seconds (100ms resolution)
  30
(Default)
= 3s

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Time delay for next motor movement 1 to 30
(Default)
= 0,1seconds - 3seconds (100ms resolution)
  5
(Default)
= 500ms