Z-Wave Products

There are over 4407 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: REM50Z (REM50Z)

Z-Wave Certification Number: ZC10-18076173


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 RS1 Sensor Cal -7 to 7
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 RS2 Lifeline Periodic Temperature Send Interval 1 to 120
(Default)
Minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 RS3 Lifeline Periodic Temperature Send Interval 1 to 120
(Default)
Minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 RS4 Lifeline Periodic Temperature Send Interval 1 to 120
(Default)
Minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 RS1 Group2 Temperature Delta Autosend Threshold 1 to 5
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 RS2 Group3 Temperature Delta Autosend Threshold 1 to 5
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 RS3 Group4 Temperature Delta Autosend Threshold 1 to 5
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 1 RS4 Group5 Temperature Delta Autosend Threshold 1 to 5
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 RS1 Group2 Periodic Temperature Send Interval 0 to 120
(Default)
Minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 RS2 Group3 Periodic Temperature Send Interval 0 to 120
(Default)
Minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 RS3 Group4 Periodic Temperature Send Interval 0 to 120
(Default)
Minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 RS4 Group5 Periodic Temperature Send Interval 0 to 120
(Default)
Minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 HVAC Thermistor Curve -7 to 7
(Default)
Degrees
  0 to 1
(Default)
0=10k Type 2, 1= 10k Type 3

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 RS1 Time Constant 1 to 60
(Default)
Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 RS2 Time Constant 1 to 60
(Default)
Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 RS3 Time Constant 1 to 60
(Default)
Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 RS4 Time Constant 1 to 60
(Default)
Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 RS3 Sensor Cal -7 to 7
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 RS4 Sensor Cal -7 to 7
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 RS1 Lifeline Temperature Delta Autosend Threshold 1 to 20
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 RS2 Lifeline Temperature Delta Autosend Threshold 1 to 20
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 RS3 Lifeline Temperature Delta Autosend Threshold 1 to 20
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 RS4 Lifeline Temperature Delta Autosend Threshold 1 to 20
(Default)
Degrees

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 RS1 Lifeline Periodic Temperature Send Interval 1 to 120
(Default)
Minutes