Z-Wave Products

There are over 3000 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z-Wave standard. Browse our Product Finder to see what Z-Wave can do for you.

Z-Wave Configuration Capabilities

Model: Motion Switch LED (40111665101)

Z-Wave Certification Number: ZC10-18076193


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 Time 5 to 900
(Default)
seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Off behaviour 0 LED is switched off and remains so until any new motion event (local or remote) is received.
  1 to 209
(Default)
LED is switched off and remains so until after a specified timeout once a new motion event (local or remote) is received. Timeout: 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution
  255 LED is switched off for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 On behaviour 0 LED is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.
  1 to 209 LED is switched on and remains so until after a specified timeout once a new motion event (local or remote) is received. It then works normally via current motion evaluation. Timeout: 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.
  255
(Default)
LED is switched on for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 On behaviour time over 0 No additional waiting for motion.
  1 to 209
(Default)
1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution
  255 Never stop waiting for motion.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 Sequence On-Off behaviour 0 LED is switched off and remains so until any new motion event (local or remote) is received.
  1 to 209
(Default)
LED is switched off and remains so until after a specified timeout once a new motion event (local or remote) is received. Timeout: 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution
  255 device ignores ON - OFF sequence and uses OFF behaviour

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 Sequence Off-On behaviour 0 LED is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.
  1 to 209
(Default)
LED is switched on and remains so until after a specified timeout once a new motion event (local or remote) is received. It then works normally via current motion evaluation. Timeout: 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.
  255 device ignores OFF - ON sequence and uses ON behaviour.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Sequence timing 10 to 50
(Default)
100 ms

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 Motion Off behaviour 0
(Default)
BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to LED endpoint, motion sensor still enabled
  1 to 209 Internal motion sensor is disabled for specified timeout after BASIC SET 0x00 to Motion sensor endpoint. BASIC to root is mapped to Motion sensor endpoint.(SPIR) Timeout: 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution
  255 BASIC SET to Motion sensor endpoint ignored, BASIC to root is mapped to LED endpoint, motion sensor still disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 Button behaviour 0 to 31
(Default)
bit field

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Button scenes 0 do not use any scene
  1 to 127
(Default)
up to scene number

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 2 Legacy inactivity time 1 to 209
(Default)
Timeout: 1..100 – 1 second (1) to 100 seconds (100) in 1-second resolution 101..200 – 1 minute (101) to 100 minutes (200) in 1-minute resolution 201..209 – 1 hour (201) to 9 hours (209) in 1-hour resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 2 Light 0 run Learn ambient light sequence
  2 to 1999 Lux
  2000
(Default)
is used as daylight (always night mode)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Sensitivity 2 to 100
(Default)
%

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Brightness measuring interval 0
(Default)
function is off
  5 to 120 minuts

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Global light 0 to 1
(Default)
binary off/on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Slave mode 0 Normal mode
  1 Slave mode
  2
(Default)
Normal mode with checking lifeline
  3 Slave mode with checking lifeline
  4 LED is permanently on