There are over 3000 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z-Wave standard. Browse our Product Finder to see what Z-Wave can do for you.

Z-Wave Configuration Capabilities

Model: Eaton’s Z-Wave Plus Wireless Switch (RF9601)

Z-Wave Certification Number: ZC10-18096234


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Delayed OFF Time Turn the switch off with a preset delay. The default is 10 seconds. You can set this anywhere between 1 second till 127 seconds. The default is set at 10

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

10 0 127 No No No

From

 

To

Description

0   127 Delayed OFF Time

Parameter Number

Parameter Size

Parameter Name

Description

13 1 BLUE LED Brightness Level while the Switch is ON Adjust the brightness of the Blue LED when switch is ON 0 = OFF 4 = Maximum brightness

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

3 0 4 No No No

From

 

To

Description

0   0 Indicator Light stays OFF
1   4 Increase the level of brightness

Parameter Number

Parameter Size

Parameter Name

Description

14 1 BLUE LED Brightness Level while the Switch is OFF Adjust brightness of the blue indicator LED with Switch is OFF 0 = OFF 4 = Maximum brightness

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 4 No No No

From

 

To

Description

0   0 Indicator Light stays OFF
1   4 Increase the level of brightness

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Panic ON Time The interval when the switch Turns ON when Panic Mode is set to ON

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 127 No No No

From

 

To

Description

0   127 Panic ON Time

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Panic OFF Time The interval when the switch Turns OFF when Panic Mode is set to ON

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 127 No No No

From

 

To

Description

0   127 Panic OFF Time

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Power Up State Power UP state allows the users to set the state the device will come ON after power is restored. 1 = OFF 2 = ON 3 = Last State Default is OFF

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 3 No No No

From

 

To

Description

1   1 Turn OFF when Power is back
2   2 Turn ON when Power is back
3   3 Default to Last State when Power is Back

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Panic Mode Enable Panic Mode allows Eaton Z-Wave devices to Turn ON/OFF at a press of button. 0 = OFF 1 = ON

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

From

 

To

Description

0   0 Panic Mode is Turned OFF