There are over 4377 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Delayed OFF Time | Press and Hold sequence for Delayed OFF. Turns off the receptacle after a set time interval. The default is 10 seconds with available values from 0 to 127 secs | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
10 | 0 | 127 | No | No | No |
From |
To |
Description |
|||
0 | 127 | Delayed OFF Time | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 1 | BLUE LED Brightness level while the receptacle is ON | Light Intensity of Indicator LED | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
3 | 0 | 4 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Indicator light stays OFF | |||
1 | 4 | Increase the brightness of indicator light | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 1 | BLUE LED Brightness level while the receptacle is OFF | Light Intensity of Indicator LED | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 4 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Indicator light stays OFF | |||
1 | 4 | Increase the brightness of indicator light | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Panic ON Time | Time interval for receptacle to be ON when Panic Mode is enabled | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 127 | No | No | No |
From |
To |
Description |
|||
0 | 127 | Interval after which device will turn ON during panic mode | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Panic OFF Time | Time interval for receptacle to be ON when Panic Mode is enabled | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 127 | No | No | No |
From |
To |
Description |
|||
0 | 127 | Interval after which device will turn OFF during panic mode | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Power Up State | 1 = OFF 2 = ON 3 = Last State | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 1 | 3 | No | No | No |
From |
To |
Description |
|||
1 | 1 | Turn OFF when power is restored | |||
2 | 2 | Turn ON when power is restored | |||
3 | 3 | Return to last state when power is restored | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Panic Mode Enabled | 0=OFF 1=ON | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | 0 | 1 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Disable Panic Mode | |||
1 | 1 | Enable Panic Mode | |||