There are over 4296 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Heatit Z-TRM2fx (Z-TRM2fx)

Z-Wave Certification Number: ZC10-18116305


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Operation Mode 0
(Default)
Off. (Default)
  1 to 0 Heating mode
  2 to 0 Cooling mode (not implemented)
  11 to 0 Energy saving heating mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Energy saving mode setpoint (ECO) 50 to 400
(Default)
5.0C – 40.0C. Default is 180 (18.0C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Cooling setpoint (COOL) 50 to 400
(Default)
5.0C – 40.0C. Default is 210 (21.0C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Floor sensor calibration -40 to 40
(Default)
-4.0C – 4.0C. Default is 0 (0.0C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 External sensor calibration -40 to 40
(Default)
-4.0C – 4.0C. Default is 0 (0.0C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Temperature display 0
(Default)
Display setpoint temperature (Default)
  1 to 0 Display setpoint temperature (Default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Button brightness – dimmed state 0 to 100
(Default)
0 – 100% (Default 50%)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 1 Button brightness – active state 0 to 100
(Default)
0 – 100% (Default 100%)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 1 Display brightness – dimmed state 0 to 100
(Default)
0 – 100% (Default 50%)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Display brightness – active state 0 to 100
(Default)
0 – 100% (Default 100%)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 2 Temperature report interval 0 Reporting of temperatures disabled
  30 to 32767
(Default)
30 seconds – 32767 seconds. Default is 60 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Sensor mode 0
(Default)
F-mode, floor sensor mode. (Default)
  3 to 0 A2-mode, external room sensor mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Temperature report hysteresis 1 to 100
(Default)
0.1C – 10.0C. Default is 10 (1.0C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 2 Meter report interval 0 Reporting of metering values is disabled
  30 to 32767
(Default)
30 seconds – 32767 seconds. Default is 60 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Meter report delta value 0 to 127
(Default)
A delta value of 0 – 12.7 kWh will result in a metering report. Default is 10 (1.0 kWh)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Floor sensor type 0
(Default)
10K NTC. (Default)
  1 to 0 12K NTC
  2 to 0 15K NTC
  3 to 0 22K NTC
  4 to 0 33K NTC
  5 to 0 47K NTC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Temperature control hysteresis (DIFF I) 3 to 30
(Default)
0.3C – 3.0C. Default is 5 (0.5C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 Floor minimum temperature limit (FLo) 50 to 400
(Default)
5.0C – 40.0C. Default is 50 (5.0C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Floor maximum temperature limit (FHi) 50 to 400
(Default)
5.0C – 40.0C. Default is 400 (40.0C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 2 Air (A2) minimum temperature limit (ALo) 50 to 400
(Default)
5.0C – 40.0C. Default is 50 (5.0C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 2 Air (A2) maximum temperature limit (AHi) 50 to 400
(Default)
5.0C – 40.0C. Default is 400 (40.0C)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 2 Heating mode setpoint (CO) 3 to 30 0.3C – 3.0C. Default is 5 (0.5C)
  50 to 400
(Default)
5.0C – 40.0C. Default is 210 (21.0C)