Z-Wave Products

There are over 4408 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart Boost Timer Switch (ZWA006-C)

Z-Wave Certification Number: ZC10-18106255


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Power out action 0 keep the last state when re-power on
  1 power on
  2 power off
  3
(Default)
return to standard schedule (see schedule command class) so this would either be on or off depending on schedule and the time.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 LED status 0 to 2
(Default)
0 - disable all LED except for boost 1 - enable all LED indication 2 - Momentary mode (LED turns on for 5 seconds, then turn off LED)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 2 kWh threshold setting 0 to 10000
(Default)
0 - disable report 1 ~ 10000 - enable report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 2 Watt threshold setting 0 to 2500
(Default)
0 - disable 1 ~ 2500 - enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 2 Current threshold setting 0 to 130
(Default)
0 - disable 1 ~ 130 - enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 4 Watt report interval 0 disable
  30 to 65535
(Default)
enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 4 kWh report interval 0 disable
  30 to 65535
(Default)
enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 4 Voltage report interval 0 disable
  30 to 65535
(Default)
enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

26 4 Current report interval 0 disable
  30 to 65535
(Default)
enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 4 Auto off timer 0 to 86400
(Default)
0 - no auto off with timer 1 ~ 86400 auto off after this specified time, unit second.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Current overload protection 0 to 1
(Default)
0 - disable current and overload protection 1 - enable current and overload protection

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 Boost time 1 to 255
(Default)
When user press the boost button one time, the boost time will increase 30 (the value can be changed) minutes.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 2 LED threshold setting 0 to 3000
(Default)
0~3000 enabled threshold