There are over 4393 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | To set which report would be sent in Report group 1 | 1 | Send Meter Report of Voltage | |
2 | Send Meter Report of Current | ||||
4 | Send Meter Report of Watt | ||||
8 | Send Meter Report of kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | To set which report would be sent in Report group 2 | 1 | Send Meter Report of Voltage | |
2 | Send Meter Report of Current | ||||
4 | Send Meter Report of Watt | ||||
8 | Send Meter Report of kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | To set which report would be sent in Report group 3 | 1 | Send Meter Report of Voltage | |
2 | Send Meter Report of Current | ||||
4 | Send Meter Report of Watt | ||||
8 | Send Meter Report of kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Set the time interval of sending Report | 1 to 2147483647 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | Set the time interval of sending Report | 1 to 2147483647 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | Set the time interval of sending Report | 1 to 2147483647 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Configure the output load status after re-power on | 0 (Default) |
The last status before the power outage. | |
1 | Always on | ||||
2 | Always off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
200 | 1 | Partner ID | 0 (Default) |
Aeon Labs Standard Product | |
1 to 127 | Others | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/disable Configuration Locked | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
254 | 2 | Device Tag | 0 to 127 (Default) |
Device Tag | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 1 | Reset the Smart Switch | 0 (Default) |
Energy mode. The LED will follow the status (on/off). | |
1 | Momentary indicate mode. When the state of Switch’s load changed, The LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action. | ||||
2 | Night light mode. The LED will remain the state that is set via the Multilevel Switch Set CC or Color Switch Set CC. | ||||
1 | Reset all configuration parameters to default. | ||||
1431655765 | Reset the Smart Switch to factory default | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Current Overload Protection. | 0 | Disabled | |
1 (Default) |
Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 4 | Set the RGB LED’s color for testing. | 0 to 255 (Default) |
Blue color value | |
256 to 65535 | Green color value | ||||
65536 to 16711680 | Red color value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
65 | 4 | To set which report would be sent in Report group 1 | 1 | Send Meter Report of Voltage | |
2 | Send Meter Report of Current | ||||
4 | Send Meter Report of Watt | ||||
8 | Send Meter Report of kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
66 | 4 | To set which report would be sent in Report group 2 | 1 | Send Meter Report of Voltage | |
2 | Send Meter Report of Current | ||||
4 | Send Meter Report of Watt | ||||
8 | Send Meter Report of kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | To set which notification would be sent to the associated nodes in association group 1 | 0 (Default) |
Nothing | |
1 | Hail CC | ||||
2 | Basic Report CC | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
83 | 4 | Configure the RGB value | 0 to 255 | Blue color value | |
256 to 65535 | Green color value | ||||
65536 to 16711680 (Default) |
Red color value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
84 | 4 | Configure the brightness level of RGB LED | 0 to 100 | The brightness of Red color | |
256 to 356 | The brightness of Yellow color | ||||
65536 to 65636 | The brightness of Green color | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
90 | 1 | Enable/disable the parameter 91 and 92 | 0 (Default) |
Disable | |
1 | Enable | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
91 | 2 | Induce an automatic report | 0 to 32767 (Default) |
The threshold can be set from 0 to 32767 watt. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
92 | 1 | Induce an automatic report | 0 to 100 (Default) |
The threshold can be set from 0 to 100%. | |