TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 1 | Status LED | Configuration of the status LED. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 3 | No | No | No |
From |
To |
Description |
|||
0 | 0 | LED turned off | |||
1 | 1 | LED turned on. (Default) | |||
2 | 2 | LED flashing at 1 second intervals (0.5 Hz). | |||
3 | 3 | LED flashing at 0.5 second interval (1 Hz). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 1 | Input 4 calibration. | Configures the functionality of input 4. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -40 | 40 | No | No | No |
From |
To |
Description |
|||
-40 | 40 | -4.0 degrees C – 4.0 degrees C. Default is 0 (0.0 degrees C). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 2 | Input 1 report interval | Time interval between consecutive temperature reports. Temperature reports can be also sent as a result of polling. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
6 | 0 | 8640 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Reporting of temperatures disabled. | |||
1 | 8640 | Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
12 | 2 | Input 2 report interval | Time interval between consecutive temperature reports. Temperature reports can be also sent as a result of polling. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
6 | 0 | 8640 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Reporting of temperatures disabled. | |||
1 | 8640 | Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
13 | 2 | Input 3 report interval | Time interval between consecutive temperature reports. Temperature reports can be also sent as a result of polling. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
6 | 0 | 8640 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Reporting of temperatures disabled. | |||
1 | 8640 | Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
14 | 2 | Input 4 report interval | Time interval between consecutive temperature reports. Temperature reports can be also sent as a result of polling. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
6 | 0 | 8640 | No | No | No |
From |
To |
Description |
|||
0 | 0 | Reporting of temperatures disabled. | |||
1 | 8640 | Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 1 | Status LED brightness level | Configure the percentage of light in the status LED, when the LED is turned on. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
50 | 0 | 100 | No | No | No |
From |
To |
Description |
|||
0 | 100 | Specifies the brightness level of the LED when it is on. Default is 50. | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 1 | Thermistor type connected to input 1 | This parameter decides which kind of thermistor that is connected to the input. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
From |
To |
Description |
|||
0 | 0 | No thermistor, input is disabled. | |||
1 | 1 | 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 1 | Thermistor type connected to input 2 | This parameter decides which kind of thermistor that is connected to the input. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
From |
To |
Description |
|||
0 | 0 | No thermistor, input is disabled. | |||
1 | 1 | 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 1 | Thermistor type connected to input 3. | This parameter decides which kind of thermistor that is connected to the input. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
From |
To |
Description |
|||
0 | 0 | No thermistor, input is disabled. | |||
1 | 1 | 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 1 | Thermistor type connected to input 4 | This parameter decides which kind of thermistor that is connected to the input. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
1 | 0 | 1 | No | No | No |
From |
To |
Description |
|||
0 | 0 | 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default) | |||
1 | 1 | 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default) | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 1 | Input 1 calibration | Configures the functionality of input 1. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -40 | 40 | No | No | No |
From |
To |
Description |
|||
-40 | 40 | -4.0 degrees C – 4.0 degrees C. Default is 0 (0.0 degrees C). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 1 | Input 2 calibration | Configures the functionality of input 2. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -40 | 40 | No | No | No |
From |
To |
Description |
|||
-40 | 40 | -4.0 degrees C – 4.0 degrees C. Default is 0 (0.0 degrees C). | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 1 | Input 3 calibration | Configures the functionality of input 3. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
0 | -40 | 40 | No | No | No |
From |
To |
Description |
|||
-40 | 40 | -4.0 degrees C – 4.0 degrees C. Default is 0 (0.0 degrees C). | |||