Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Heatit Z-Water (Z-Water)

Z-Wave Certification Number: ZC10-19036400


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Status LED Configuration of the status LED.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 3 No No No

From

 

To

Description

0   0 LED turned off
1   1 LED turned on. (Default)
2   2 LED flashing at 1 second intervals (0.5 Hz).
3   3 LED flashing at 0.5 second interval (1 Hz).

Parameter Number

Parameter Size

Parameter Name

Description

10 1 Input 4 calibration. Configures the functionality of input 4.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 -40 40 No No No

From

 

To

Description

-40   40 -4.0 degrees C – 4.0 degrees C. Default is 0 (0.0 degrees C).

Parameter Number

Parameter Size

Parameter Name

Description

11 2 Input 1 report interval Time interval between consecutive temperature reports. Temperature reports can be also sent as a result of polling.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 0 8640 No No No

From

 

To

Description

0   0 Reporting of temperatures disabled.
1   8640 Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds).

Parameter Number

Parameter Size

Parameter Name

Description

12 2 Input 2 report interval Time interval between consecutive temperature reports. Temperature reports can be also sent as a result of polling.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 0 8640 No No No

From

 

To

Description

0   0 Reporting of temperatures disabled.
1   8640 Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds).

Parameter Number

Parameter Size

Parameter Name

Description

13 2 Input 3 report interval Time interval between consecutive temperature reports. Temperature reports can be also sent as a result of polling.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 0 8640 No No No

From

 

To

Description

0   0 Reporting of temperatures disabled.
1   8640 Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds).

Parameter Number

Parameter Size

Parameter Name

Description

14 2 Input 4 report interval Time interval between consecutive temperature reports. Temperature reports can be also sent as a result of polling.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

6 0 8640 No No No

From

 

To

Description

0   0 Reporting of temperatures disabled.
1   8640 Multiply with 10 seconds, 10 seconds – 24 hours. Default is 6 (60 seconds).

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Status LED brightness level Configure the percentage of light in the status LED, when the LED is turned on.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

50 0 100 No No No

From

 

To

Description

0   100 Specifies the brightness level of the LED when it is on. Default is 50.

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Thermistor type connected to input 1 This parameter decides which kind of thermistor that is connected to the input.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

From

 

To

Description

0   0 No thermistor, input is disabled.
1   1 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default)

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Thermistor type connected to input 2 This parameter decides which kind of thermistor that is connected to the input.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

From

 

To

Description

0   0 No thermistor, input is disabled.
1   1 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default)

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Thermistor type connected to input 3. This parameter decides which kind of thermistor that is connected to the input.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

From

 

To

Description

0   0 No thermistor, input is disabled.
1   1 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default)

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Thermistor type connected to input 4 This parameter decides which kind of thermistor that is connected to the input.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

From

 

To

Description

0   0 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default)
1   1 10K NTC. (PART NUMBER: TT02-10KC3-93D-3000R-TPH). (Default)

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Input 1 calibration Configures the functionality of input 1.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 -40 40 No No No

From

 

To

Description

-40   40 -4.0 degrees C – 4.0 degrees C. Default is 0 (0.0 degrees C).

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Input 2 calibration Configures the functionality of input 2.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 -40 40 No No No

From

 

To

Description

-40   40 -4.0 degrees C – 4.0 degrees C. Default is 0 (0.0 degrees C).

Parameter Number

Parameter Size

Parameter Name

Description

9 1 Input 3 calibration Configures the functionality of input 3.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 -40 40 No No No

From

 

To

Description

-40   40 -4.0 degrees C – 4.0 degrees C. Default is 0 (0.0 degrees C).