There are over 4409 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Low Battery Power Level | 10 to 50 (Default) |
Low Battery Power Level of alarm threshold values | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
100 | 1 | Set 101 ~ 104 to default | 0 (Default) |
Set 101 ~ 104 to default | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | The interval time of sending the temperature reporting | 0 | the temperature reporting is disabled | |
1 to 2678400 (Default) |
The interval time of sending the temperature reporting is 1 seconds to 31 days = 2678400 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | The interval time of sending the humidity reporting. | 0 | the humidity reporting is disabled | |
1 to 2678400 (Default) |
The interval time of sending the humidity reporting is 1 seconds to 31 days = 2678400 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | The interval time of sending the luminance reporting. | 0 | the luminance reporting is disabled | |
1 to 2678400 (Default) |
The interval time of sending the luminance reporting is 1 seconds to 31 days = 2678400 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
104 | 4 | The interval time of sending the battery level reporting. | 0 | the battery level reporting is disabled | |
1 to 2678400 (Default) |
The interval time of sending the battery level reporting is 1 seconds to 31 days = 2678400 seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 1 | Enable 111 ~ 114 temperature/humidity/luminance/ battery level change reporting. | 0 (Default) |
Disabled | |
1 to 0 | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 2 | Configuration temperature change threshold. | 1 to 500 (Default) |
the temperature change threshold value(unit 0.1℃) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 1 | Configuration humidity change threshold. | 1 to 32 (Default) |
humidity change threshold value(unit %) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 2 | Configuration luminance change threshold. | -32767 to -1 | luminance change threshold is 32767 to 65528 | |
0 to 32766 (Default) |
luminance change threshold is 0 to 32766 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
114 | 1 | Configuration battery level change threshold. | 1 to 100 (Default) |
battery level change threshold value(unit)% | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Turn on/off PIR + Set Sensitivity | 0 to 10 (Default) |
0x0A indicates the highest sensitivity, 0x00 means off PIR detection function. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | PIR triggers the waiting time value | 5 to 15300 (Default) |
the waiting time of the PIR triggering in Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Whether the BASIC SET command is sent after the PIR is triggered | 0 (Default) |
Unabled | |
1 to 0 | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | PIR triggers the correspondence between the value of the Basic set and the PIR state | 0 (Default) |
PIR triggers Send the basic set command 0xff PIR alarm release send the basic set command 0x00 | |
1 to 0 | PIR triggers send the basic set command 0x00 PIR alarm release send the basic set command 0xff. | ||||