Z-Wave Products

There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: ABUS Z-Wave Multisensor (SHBW10000)

Z-Wave Certification Number: ZC10-19016351


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Low Battery Power Level 10 to 50
(Default)
Low Battery Power Level of alarm threshold values

Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Set 101 ~ 104 to default 0
(Default)
Set 101 ~ 104 to default

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 The interval time of sending the temperature reporting 0 the temperature reporting is disabled
  1 to 2678400
(Default)
The interval time of sending the temperature reporting is 1 seconds to 31 days = 2678400 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 The interval time of sending the humidity reporting. 0 the humidity reporting is disabled
  1 to 2678400
(Default)
The interval time of sending the humidity reporting is 1 seconds to 31 days = 2678400 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 The interval time of sending the luminance reporting. 0 the luminance reporting is disabled
  1 to 2678400
(Default)
The interval time of sending the luminance reporting is 1 seconds to 31 days = 2678400 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

104 4 The interval time of sending the battery level reporting. 0 the battery level reporting is disabled
  1 to 2678400
(Default)
The interval time of sending the battery level reporting is 1 seconds to 31 days = 2678400 seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 1 Enable 111 ~ 114 temperature/humidity/luminance/ battery level change reporting. 0
(Default)
Disabled
  1 to 0 Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 2 Configuration temperature change threshold. 1 to 500
(Default)
the temperature change threshold value(unit 0.1℃)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 1 Configuration humidity change threshold. 1 to 32
(Default)
humidity change threshold value(unit %)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 2 Configuration luminance change threshold. -32767 to -1 luminance change threshold is 32767 to 65528
  0 to 32766
(Default)
luminance change threshold is 0 to 32766

Parameter Number

Parameter Size

Parameter Name

Parameter Values

114 1 Configuration battery level change threshold. 1 to 100
(Default)
battery level change threshold value(unit)%

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Turn on/off PIR + Set Sensitivity 0 to 10
(Default)
0x0A indicates the highest sensitivity, 0x00 means off PIR detection function.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 PIR triggers the waiting time value 5 to 15300
(Default)
the waiting time of the PIR triggering in Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Whether the BASIC SET command is sent after the PIR is triggered 0
(Default)
Unabled
  1 to 0 Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 PIR triggers the correspondence between the value of the Basic set and the PIR state 0
(Default)
PIR triggers Send the basic set command 0xff PIR alarm release send the basic set command 0x00
  1 to 0 PIR triggers send the basic set command 0x00 PIR alarm release send the basic set command 0xff.