There are over 4228 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Locally Button function | 0 (Default) |
Up Button ON,Down Button OFF | |
1 | Up Button OFF,Down Button ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Multilevel minimum value can be set(The minimum luminance value of the dimming) | 0 to 99 (Default) |
Multilevel minimum value can be set(The minimum luminance value of the dimming) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Multilevel maxmum value can be set(The maxmum luminance value of the dimming) | 0 to 99 (Default) |
Multilevel maxmum value can be set(The maxmum luminance value of the dimming) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | when switch is off and quickly press UPPER paddle 2 times, switch turns on to x brightness | 0 (Default) |
turn on to 99 | |
1 | turn on to the value relate with parameter 11 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Status LED Configuration | 0 (Default) |
Output ON,Led OFF. | |
1 | OutputOFF,Led ON. | ||||
2 | Always OFF | ||||
3 | Always ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Count Down Configuration(Turn off the output by time) | 0 (Default) |
Auto Turn-OFF Timer Disabled | |
1 | Auto Turn-OFF Timer Enabled | ||||
0 to 65535 (Default) |
Count Down Configuration(Turn off the output by time) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Enable Auto Turn-ON Timer | 0 (Default) |
Auto Turn-ON Timer Disabled | |
1 | Auto Turn-ON Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Count Down Configuration(Turn ON the output by time) | 0 to 65535 (Default) |
Count Down Configuration(Turn ON the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Association Setting Parameter | 0 | None | |
1 (Default) |
Local | ||||
2 | 3-way | ||||
3 | 3-way&ocal | ||||
4 | Z-Wave Hub | ||||
5 | Z-Wave Hub&Local | ||||
6 | Z-Wave Hub &3-way | ||||
7 | Z-Wave hub&Local&3-way | ||||
8 | Timer | ||||
0 | |||||
0 | |||||
9 | Timer&Local | ||||
10 | Timer &3-way | ||||
11 | Timer &3-way&Local | ||||
12 | Timer&Z-Wave Hub | ||||
13 | Timer&Z-Wave hub&Local | ||||
14 | Timer&Z-Wave hub&3-way | ||||
15 | All | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Restores state after power failure | 0 | Output OFF | |
1 | Output ON | ||||
2 (Default) |
The state before a power outage. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Dimmer Speed Parameter | 1 to 99 (Default) |
Dimmer Speed need xx S | |