There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Restores state after power failure | 0 (Default) |
The state before a power outage. | |
1 | outlet on | ||||
2 | outlet off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Endpoint1 Enable Auto Turn-ON Timer | 0 (Default) |
EP1 Auto Turn-ON Timer Disabled | |
1 | EP1 Auto Turn-ON Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 4 | Endpoint1 Count Down Configuration(Turn on the output by time) | 1 to 65535 (Default) |
Endpoint1 Count Down Configuration(Turn on the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Endpoint2 Enable Auto Turn-OFF Timer | 0 (Default) |
EP2 Auto Turn-OFF Timer Disabled | |
1 | EP2 Auto Turn-OFF Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 4 | Endpoint2 Count Down Configuration(Turn off the output by time) | 1 to 65535 (Default) |
Endpoint2 Count Down Configuration(Turn off the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Endpoint2 Enable Auto Turn-ON Timer | 0 (Default) |
EP2 Auto Turn-ON Timer Disabled | |
1 | EP2 Auto Turn-ON Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 4 | Endpoint2 Count Down Configuration(Turn on the output by time) | 1 to 65535 (Default) |
Endpoint2 Count Down Configuration(Turn on the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Manual Control | 0 | Manual Control Disabled | |
1 (Default) |
Manual Control Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 1 | Status LED Configuration | 0 | LED indicator will display power consumption whenever the device is plugged in | |
1 (Default) |
LED indicator will display power consumption whenever the device is ON in and will turn off when the plug is OFF | ||||
2 | LED indicator will display the level of power consumption for 5 seconds only whenever the device is turned on or off | ||||
3 | Always OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 4 | Power Wattage Report Value Threshold(Wattage) | 0 to 10 (Default) |
Power Wattage Report Value Threshold(Wattage) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 4 | Energy (kWh) Report Frequency (Timer) | 30 to 2678400 (Default) |
Energy (kWh) Report Frequency (Timer) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 4 | Voltage (V) Report Frequency (Timer) | 30 to 2678400 (Default) |
Voltage (V) Report Frequency (Timer) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 4 | Electricity (A) Report Frequency (Timer) | 0 to 30 | Power Wattage Report Value Threshold(Wattage) | |
30 to 2678400 (Default) |
Electricity (A) Report Frequency (Timer) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Overload Protection (Current) | 1 to 16 (Default) |
Overload Protection (Current) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Endpoint1 Enable Auto Turn-OFF Timer | 0 (Default) |
EP1 Auto Turn-OFF Timer Disabled | |
1 | EP1 Auto Turn-OFF Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 4 | Endpoint1 Count Down Configuration(Turn off the output by time) | 1 to 65535 (Default) |