TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Restores state after power failure | 0 (Default) |
The state before a power outage | |
1 | Output ON | ||||
2 | Output OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Endpoint2 Enable Auto Turn-OFF Timer | 0 (Default) |
EP2 Auto Turn-OFF Timer Disabled | |
1 | EP2 Auto Turn-OFF Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 4 | Endpoint2 Count Down Configuration(Turn off the output by time) | 1 to 65535 (Default) |
Endpoint1 Count Down Configuration(Turn off the output by time) | |
1 to 65535 (Default) |
Endpoint2 Count Down Configuration(Turn off the output by time) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Endpoint2 Enable Auto Turn-ON Timer | 0 (Default) |
EP2 Auto Turn-ON Timer Disabled | |
1 | EP2 Auto Turn-ON Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 4 | Endpoint2 Count Down Configuration(Turn on the output by time) | 1 to 65535 (Default) |
Endpoint2 Count Down Configuration(Turn on the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Endpoint3 Enable Auto Turn-OFF Timer | 0 (Default) |
EP3 Auto Turn-OFF Timer Disabled | |
1 | EP3 Auto Turn-OFF Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 4 | Endpoint3 Count Down Configuration(Turn off the output by time) | 1 to 65535 (Default) |
Endpoint3 Count Down Configuration(Turn off the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Endpoint3 Enable Auto Turn-ON Timer | 0 (Default) |
EP3 Auto Turn-ON Timer Disabled | |
1 | EP3 Auto Turn-ON Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
17 | 4 | Endpoint3 Count Down Configuration(Turn on the output by time) | 1 to 65535 (Default) |
Endpoint3 Count Down Configuration(Turn on the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Endpoint4 Enable Auto Turn-OFF Timer | 0 (Default) |
EP4 Auto Turn-OFF Timer Disabled | |
1 | EP4 Auto Turn-OFF Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 4 | Endpoint4 Count Down Configuration(Turn off the output by time) | 1 to 65535 (Default) |
Endpoint4 Count Down Configuration(Turn off the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 4 | Power Wattage Report Value Threshold(Wattage) | 0 to 65536 (Default) |
Power Wattage Report Value Threshold(Wattage) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Endpoint4 Enable Auto Turn-ON Timer | 0 (Default) |
EP4 Auto Turn-ON Timer Disabled | |
1 | EP4 Auto Turn-ON Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 4 | Endpoint4 Count Down Configuration(Turn on the output by time) | 1 to 65535 (Default) |
Endpoint4 Count Down Configuration(Turn on the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Endpoint5 Enable Auto Turn-OFF Timer | 0 (Default) |
EP5 Auto Turn-OFF Timer Disabled | |
1 | EP5 Auto Turn-OFF Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 4 | Endpoint5 Count Down Configuration(Turn off the output by time) | 1 to 65535 (Default) |
Endpoint5 Count Down Configuration(Turn off the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
24 | 1 | Endpoint5 Enable Auto Turn-ON Timer | 0 (Default) |
EP5 Auto Turn-ON Timer Disabled | |
1 | EP5 Auto Turn-ON Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
25 | 4 | Endpoint5 Count Down Configuration(Turn on the output by time) | 1 to 65535 (Default) |
Endpoint5 Count Down Configuration(Turn on the output by time) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
26 | 1 | Manual Control | 0 | Manual Control Disabled | |
1 (Default) |
Manual Control Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Status LED Configuration | 0 | Output ON,Led ON. | |
1 (Default) |
Output ON,Led OFF. | ||||
2 | Always OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 4 | Power Wattage Report Frequency (Timer)Power Wattage Report Frequency (Time | 30 to 26784000 (Default) |
Power Wattage Report Frequency (Time | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 4 | Energy (kWh) Report Frequency (Timer) | 30 to 2678400 (Default) |
Energy (kWh) Report Frequency (Timer) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 2 | Energy (kWh) Report Frequency (Wattage) | 0 to 1800 (Default) |
Energy (kWh) Report Frequency (Wattage) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Endpoint1 Enable Auto Turn-OFF Timer | 0 (Default) |
EP1 Auto Turn-OFF Timer Disabled | |
1 | EP1 Auto Turn-OFF Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Endpoint1 Enable Auto Turn-ON Timer | 0 (Default) |
EP1 Auto Turn-ON Timer Disabled | |
1 | EP1 Auto Turn-ON Timer Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 4 | Endpoint1 Count Down Configuration(Turn on the output by time) | 1 to 65535 (Default) |
Endpoint1 Count Down Configuration(Turn on the output by time) | |