Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Parameter no. 11 - Turn Smart plug 16A Off Automatically with Timer | 0 (Default) |
Auto OFF Disabled | |
1 to 32535 | 1 - 32535 seconds. Auto OFF timer enabled for a given number of seconds. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Parameter no. 12 - Turn Smart plug 16A On Automatically with Timer | 0 (Default) |
Auto ON Disabled | |
1 to 32535 | 1 - 32535 seconds. Auto ON timer enabled- for a given amount of seconds. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Parameter no. 30 - Restore on/off status for Smart plug 16A after power failure | 0 (Default) |
Device saves last on/off status and restores it after a power failure. | |
1 to 0 | Device does not save on/off status and does not restore it after a power failure, it remains off. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 1 | Parameter no. 40 – Watt Power Consumption Reporting Threshold for Smart plug 16A | 0 | Power consumption reporting disabled | |
1 to 100 (Default) |
1% - 100% Power consumption reporting enabled. New value is reported only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 2 | Parameter no. 42 – Watt Power Consumption Reporting Time Threshold for Smart plug 16A Load | 0 (Default) |
Power consumption reporting on time interval disabled | |
30 to 32535 | 30 - 32535 seconds. Power consumption reporting enabled. Report is sent according to time interval (value) set here. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 2 | Parameter no. 50 – Down value | 0 to 4000 (Default) |
0W – 4000 W power threshold | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
51 | 2 | Parameter no. 51 – Up value | 0 to 4000 (Default) |
0 W – 4000 W power threshold | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
52 | 1 | Parameter no. 52 - Action in case of exceeding defined power values (parameters 50 and 51) | 0 | function inactive | |
1 to 0 | turn the associated devices on, once the power drops below Down value (parameter no. 50) | ||||
2 to 0 | turn the associated devices off, once the power drops below Down value (parameter no. 50) | ||||
3 to 0 | turn the associated devices on, once the power rises above Up value (parameter no. 51) | ||||
4 to 0 | turn the associated devices off, once the power rises above Up value (parameter no. 51) | ||||
5 to 0 | 1 and 4 combined. Turn the associated devices on, once the power drops below Down value (parameter no. 50). Turn the associated devices off, once the power rises above Up value (parameter no. 51). | ||||
6 to 0 | 2 and 3 combined. Turn the associated devices off, once the power drops below Down value (parameter 50). Turn the associated devices on, once the power rises above Up value (parameter no. 51). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
70 | 2 | Parameter no. 70 - Overload safety switch | 1 to 4000 | 1 W – 4000W | |
0 (Default) |
function not active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
71 | 2 | Parameter no. 71 – Power threshold | 0 (Default) |
function not active | |
1 to 4000 | 1 W – 4000W | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
72 | 1 | Parameter no. 72 – Time interval | 0 | immediate sending of notification when active power drops bellow threshold set in parameter 71 | |
0 to 125 (Default) |
0 – 125 minutes | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
73 | 1 | Parameter no. 73 – Turn Smart Plug OFF | 0 | function disabled | |
1 to 0 | turn OFF relay once the notification Program completed is sent | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
74 | 1 | Parameter no. 74 – Enable/disable LED | 0 | LED is disabled | |
1 to 0 | LED is enabled | ||||