TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: S2 Dimmer (ZEN27)

Z-Wave Certification Number: ZC10-18116309


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Paddle Control 0
(Default)
Upper paddle turns the light on, lower paddle turns the light off
  1 Upper paddle turns the light off, lower paddle turns the light on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Minimum Brightness 1 to 99
(Default)
% brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Maximum Brightness 1 to 99
(Default)
% brightness

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Double Tap Function 0
(Default)
the light will turn on to full brightness with double tap (default)
  1 the light will turn on to the maximum brightness level set in Parameter 11 with double tap

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 LED Indicator Control 0
(Default)
LED indicator is on when switch is off, LED indicator is off when switch is on
  1 LED indicator is on when switch is on, LED indicator is off when switch is off
  2 LED indicator is always OFF
  3 LED indicator is always ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Enable/Disable Auto Turn-Off Timer 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 4 Set Auto Turn-Off Timer 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Enable/Disable Auto Turn-On Timer 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Set Auto Turn-On Timer 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 On Off Status After Power Failure 0 forced to OFF (regardless of state prior to power outage)
  1 forced to ON (regardless of state prior to power outage)
  2
(Default)
remembers and restores on/off status after power failure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Ramp Rate Control 1 to 99
(Default)
seconds