Z-Wave Products

There are over 4391 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: 5-Outlet Power Strip (ZEN20 VER. 2.0)

Z-Wave Certification Number: ZC10-18116311


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 On/Off Status Recovery A􀈇er Power Failure 0
(Default)
Power Strip remembers the status for each outlet prior to power outage and turns back to it
  1 Power Strip automatically turns ON for each outlet once power is restored (it does not remember the status prior to power outage)
  2 Power Strip automatically turns OFF each outlet once power is restored (it does not remember the status prior to power outage)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Enable/ Disable Auto Turn-Off Timer for CH2 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 4 Set Auto Turn-Off Timer for CH2 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Enable/ Disable Auto Turn-On Timer for CH2 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 4 Set Auto Turn-On Timer for CH2 1 to 65535
(Default)
minutes
  0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Enable/ Disable Auto Turn-Off Timer for CH3 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 4 Set Auto Turn-Off Timer for CH3 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 1 Enable/ Disable Auto Turn-On Timer for CH3 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

17 4 Set Auto Turn-On Timer for CH3 1 to 65535
(Default)
minutes
  0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 Enable/ Disable Auto Turn-Off Timer for CH4 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 4 Set Auto Turn-Off Timer for CH4 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 4 Power Wattage Report Value Threshold 0 Power meter disabled
  1 to 65535
(Default)
Watts

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Enable/ Disable Auto Turn-On Timer for CH4 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 4 Set Auto Turn-On Timer for CH4 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Enable/ Disable Auto Turn-Off Timer for CH5 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 4 Set Auto Turn-Off Timer for CH5 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Enable/ Disable Auto Turn-On Timer for CH5 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 4 Set Auto Turn-On Timer for CH5 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

26 1 Manual Control 0 manual control disabled for all outlets
  1
(Default)
manual control enabled for all outlets

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 LED Indicator Mode 0 LED indicator is on when power is of and off when power is on
  1
(Default)
LED indicator is on when power is on and off when power is off
  2 LED indicator is always off, regardless of power status.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 4 Power Wattage Report Frequency 30 to 2678400
(Default)
seconds
  0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 4 Energy (kWh) Report Frequency 30 to 2678400
(Default)
2678400
  0

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 Overload Protection 0 overload protection disabled
  1 to 1800
(Default)
Watts

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Enable/ Disable Auto Turn-Off Timer for CH1 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 4 Set Auto Turn-Off Timer for CH1 1 to 65535
(Default)
minutes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Enable/ Disable Auto Turn-On Timer for CH1 0
(Default)
timer disabled
  1 timer enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 4 Set Auto Turn-On Timer for CH1 1 to 65535
(Default)
minutes
  0