Z-Wave Products

There are over 4409 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Slim Smart Door/Window Sensor (43973/ZW6305)

Z-Wave Certification Number: ZC10-19016363


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Reverse open/close detection This parameter allows you to reverse the detection values of the device.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No Yes

From

 

To

Description

0   0 (Default) Disabled
1   1 Reverse event (Open 16, Close 17)

Parameter Number

Parameter Size

Parameter Name

Description

19 1 Alternate exclusion This parameter allows you to enable the alternate exclusion method that is available for this device.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

From

 

To

Description

0   0 (Default) Disabled
1   1 Enabled

Parameter Number

Parameter Size

Parameter Name

Description

20 1 Inclusion Configuration This parameter allows you to change the inclusion configuration settings of this device.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 2 No No No

From

 

To

Description

1   1 (Default) - Notification Only
2   2 Notification and Basic Report

Parameter Number

Parameter Size

Parameter Name

Description

21 1 LED Control (Magnet triggers only) This parameter gives you the option to turn the LED off on magnetic triggers.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

From

 

To

Description

0   0 (Default) - Enabled
1   1 Disabled

Parameter Number

Parameter Size

Parameter Name

Description

23 2 Battery Report Interval This parameter allows you to choose how often the battery level is reported.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1440 5 1440 No No No

From

 

To

Description

5   60 5-60 Minutes
360   360 6 Hours
720   720 12 Hours
1440   1440 (Default) Daily

Parameter Number

Parameter Size

Parameter Name

Description

53 1 Tamper LED Control This parameter allows you to choose how often the LED will flash once the device/battery cover is tampered with.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 1 2 No No No

From

 

To

Description

1   1 (Default) Continuous Flash
2   2 Flashes once, on initial tamper only