Z-Wave Products

There are over 4393 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Wall Plug JP (FGWPA-111)

Z-Wave Certification Number: ZC10-19016342


Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Power reporting 0
(Default)
power reports inactive
  1 to 100 power change in percent

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Energy reporting threshold 0
(Default)
energy reports inactive
  1 to 500 (0.01-5kWh, step 0.01kWh) - threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 Periodic power reporting 0 periodic reports inactive
  30 to 32400
(Default)
(in seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 Periodic energy reporting 0 periodic reports inactive
  30 to 32400
(Default)
(in seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Measuring energy consumed by the Wall Plug itself 0
(Default)
function inactive
  1 function active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Remember device status before the power failure 0 device remains switched off
  1
(Default)
device restores the state from before the power failure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 2 UP value - „On/Off (Power)” association group (3) 100 to 18000
(Default)
(10.0-1800.0W, step 0.1W)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 2 DOWN value - „On/Off (Power)” association group (3) 0 to 17900
(Default)
(0.0-1790.0W, step 0.1W)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Controlling „On/Off (Power)” association group (3) 1 send frame (with value set in parameter 26) only if power exceeded value of parameter 21
  2 send frame (with value set in parameter 27) only if power dropped below value of parameter 22
  3
(Default)
send frame in both cases

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 2 SWITCH ON value - „On/Off (Button)” association group (2) 0 turning off associated devices
  1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 SWITCH OFF value - „On/Off (Button)” association group (2) 0
(Default)
turning off associated devices
  1 to 99 forcing level of associated devices
  255 setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

26 2 THRESHOLD UP value - „On/Off (Power)” association group (3) 0 turning off associated devices
  1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 2 THRESHOLD DOWN value - „On/Off (Power)” association group (3) 0
(Default)
turning off associated devices
  1 to 99 forcing level of associated devices
  255 setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 2 Overload safety switch 0
(Default)
function inactive
  10 to 18000 1.0-1800.0W, step 0.1W) - power threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Active alarms 1 general alarm
  2 smoke alarm
  4 CO alarm
  8 CO2 alarm
  16 high temperature alarm
  32 flood alarm
  64 all

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 1 Response to alarm frames 0
(Default)
no reaction
  1 turn connected device on
  2 turn connected device off
  5 to 50 (0.5-5.0s, step 0.1s) - cyclically change device state with set period

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 2 Alarm state duration 1 to 32400
(Default)
(in seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 2 Power load for violet color 1000 to 18000
(Default)
(100.0-1800.0W, step 0.1W)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 LED frame color when controlled device is on 0 illumination turned off completely
  1
(Default)
color changes smoothly depending on active power
  2 color changes in steps depending on active power
  3 white
  4 red
  5 green
  6 blue
  7 yellow
  8 cyan
  9 magenta

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 1 LED frame color when controlled device is off 0
(Default)
illumination turned off completely
  1 LED frame is illuminated with a color corresponding to the last measured power, before the controlled device was turned off
  3 white
  4 red
  5 green
  6 blue
  7 yellow
  8 cyan
  9 magenta

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 1 LED frame color at the Z-Wave network alarm detection 0 illumination turned off completely
  1 no change in color. LED frame color is determined by settings of parameters 41 or 42
  2
(Default)
LED frame flashes red/blue/white
  3 white
  4 red
  5 green
  6 blue
  7 yellow
  8 cyan
  9 magenta