Z-Wave Products

There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: TriSensor (ZWA005-S)

Z-Wave Certification Number: ZC10-19026380


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 Motion Retrigger Time 0 to 32767
(Default)
Value = 0 will disable PIR sensor from triggering until motion timeout has finished.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Led Indicate Disable 0 to 1
(Default)
‘1’ – Enable Led Blink when device detects a motion event. ‘0’ – Disable Led Blink. This configuration is not affect inclusion, exclusion and reset.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 2 Light Sensor Calibrated Coefficient 1 to 32767
(Default)
Scale: Lux.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Led Color For Motion Event Report ‘0’ – Disable. 0 to 8
(Default)
‘0’ – Disable. ‘1’ – Red. ‘2’ – Green. ‘3’ – Blue. ‘4’ – Yellow. ‘5’ – Pink. ‘6’ – Cyan. ‘7’ – Purple. ‘8’ – Orange.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Led Color For Temperature Sensor Report 0 to 8
(Default)
‘0’ – Disable. ‘1’ – Red. ‘2’ – Green. ‘3’ – Blue. ‘4’ – Yellow. ‘5’ – Pink. ‘6’ – Cyan. ‘7’ – Purple. ‘8’ – Orange.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Led Color For Light Sensor Report 0 to 8
(Default)
‘0’ – Disable. ‘1’ – Red. ‘2’ –Green. ‘3’ – Blue. ‘4’ – Yellow. ‘5’ – Pink. ‘6’ – Cyan. ‘7’ – Purple. ‘8’ – Orange.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Led Color For Wakeup Notification Report 0 to 8
(Default)
‘0’ – Disable. ‘1’ – Red. ‘2’ –Green. ‘3’ – Blue. ‘4’ – Yellow. ‘5’ – Pink. ‘6’ – Cyan. ‘7’ – Purple. ‘8’ – Orange.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 2 Motion Clear Time 1 to 32767
(Default)
Unit: Second.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Temperature Scale Setting 0 to 8
(Default)
‘0’ – Disable. ‘1’ – Red. ‘2’ –Green. ‘3’ – Blue. ‘4’ – Yellow. ‘5’ – Pink. ‘6’ – Cyan. ‘7’ – Purple. ‘8’ – Orange.
  0 to 1
(Default)
0 – Celsius (C). 1 – Fahrenheit (F).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 2 Temperature Threshold Value to Report 0 to 250
(Default)
Temperature Threshold Value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 2 Light intensity Threshold Value to Report 0 to 10000
(Default)
Scale: Lux.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 2 Temperature Sensor Report Interval 1 to 32767
(Default)
Unit: Second.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 2 Light Sensor Report Interval 1 to 32767
(Default)
Unit: Second.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Motion Sensitivity 0 to 11
(Default)
0 – PIR sensor disabled. 1 – Lowest sensitivity. 11– Highest sensitivity.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 2 Temperature Offset Value -200 to 200
(Default)
Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 2 Light Intensity Offset Value -1000 to 1000
(Default)
Scale: Lux.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Binary Sensor Report Enable 0 to 1
(Default)
‘0’ –Disable sensor binary report when motion event is detected or cleared. ‘1’ –Enable sensor binary report when motion event is detected or cleared.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Disable BASIC_SET to Associated nodes 0 to 3
(Default)
0 – Disabled All Group Basic Set Command 1 – Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is disabled. 2 – Enabled Group 3 Basic Set Command, Group 2 Basic Set Command is disabled. 3 – Enabled Group 2 and Group 3 Basic Set Command.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Basic Set Value Settings for Group 2 0 to 5
(Default)
‘0’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is cleared. ‘1’– Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is cleared. ‘2’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered. ‘3’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered. ‘4’ – Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is cleared. ‘5’ – Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is cleared.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 2 Temperature Alarm Value -400 to 850
(Default)
Value = [Value] * 0.1(Celsius / Fahrenheit)