There are over 4121 interoperable
Group ID | Group Profile Name | Profile | Maximum Nodes | Description | Endpoint ID | Commands |
---|---|---|---|---|---|---|
1 | 1 | Group 1 for “LifeLine” (max node = 1): Notification CC,V3 (COMMAND_CLASS_NOTIFICATION) Battery CC (COMMAND_CLASS_BATTERY) Device Reset Locally CC Notification Report 1. If Glass Break Detector is triggered, it will send a Notification Report (Type: 0x07, Event 0x06). 2. If tamper is open, it will send Notification Report (Type: 0x07, Event: 0x03) 3. If tamper is closed, it will send Notification Report (Type: 0x07, Event: 0x00, Parmeter:0x03). Battery Report 1. If battery level changes, it will send Battery Report (0x64, 0x4B, 0x32, 0x19, or 0xFF) respectively. 0x64 --- 100% Battery Full 0x4B --- 75% Battery 0x32 --- 50% Battery 0x19 --- 25% Battery 0xFF --- Battery Dead (Cut Off) Device Reset 1. To perform factory reset, press and hold the Function Button for 10 seconds, the device will send a DEVICE_RESET_LOCALLY_NOTIFICATION report. | 0 | |||
2 | 1 | Group 2 for “Basic Set” (max node = 1): BASIC CC (COMMAND_CLASS_BASIC) 1. When the detector is triggered, it will send BASIC SET (0xFF). The device does NOT support Restore Event report. | 0 |