TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Minimum Temperature change to report | 0 | disabled | |
1 to 100 (Default) |
1/10 degree | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | High Temperature Trigger BASIC Set Command Value | 0 to -1 | value | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Low Humidity Trigger BASIC Set Command Value | 0 to -1 | value | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | High Humidity Trigger BASIC Set Command Value | 0 to -1 | value | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Minimum humidity change to report | 0 | disabled | |
1 to 20 (Default) |
% | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Periodic Reports | 0 | disabled | |
900 to -1 | seconds | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 2 | Temperature Upper Watermark value | 0 (Default) |
disabled | |
1 to 1000 | 1/10 degree | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Temperature Lower Watermark value | 0 (Default) |
disabled | |
-200 to 1000 (Default) |
1/10 degree | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Humidity Upper Watermark value | 0 (Default) |
disabled | |
10 to 100 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Humidity Lower Watermark value | 0 (Default) |
disabled | |
1 to 90 | % | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Low Temperature Trigger BASIC Set Command Value | 0 to -1 | value | |