Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Heatit Z-Dim (Z-Dim)

Z-Wave Certification Number: ZC10-19106778


Parameter Number

Parameter Size

Parameter Name

Description

1 1 Connected Load. The parameter defines the value of connected load. Refer to Paragraph 8 ”Power Metering”.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 200 No No No

From

 

To

Description

0   0 Not configured (Default)
1   200 1-200 Watts connected load

Parameter Number

Parameter Size

Parameter Name

Description

10 1 Power restore level. The parameter defines initial dimming level after power loss.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

50 1 99 No No No

From

 

To

Description

1   99 1% - 99% Default is 50 (50%)

Parameter Number

Parameter Size

Parameter Name

Description

2 1 Minimum Dim level. The parameter defines the lowest dimming level of the dimmer. The value must be lower than parameter 3 ”Maximum Dim Level”.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

20 1 98 No No No

From

 

To

Description

1   98 1% - 98% Default is 20 (20%)

Parameter Number

Parameter Size

Parameter Name

Description

3 1 Maximum Dim level. The parameter defines the highest dimming level of the dimmer. The value must be higher than parameter 2 ”Minimum Dim Level”.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

85 2 99 No No No

From

 

To

Description

2   99 2% - 99% Default is 85 (85%)

Parameter Number

Parameter Size

Parameter Name

Description

4 1 Total steps. The parameter defines how many steps it should take to dim from minimum to maximum dim level. (One round = 20 steps)

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

15 5 255 No No No

From

 

To

Description

5   255 5-255 steps. Default is 15 (3/4 round)

Parameter Number

Parameter Size

Parameter Name

Description

5 1 Double press function. The parameter defines the double press functionality.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 1 No No No

From

 

To

Description

0   0 Central Scene notification (Default)
1   1 Dim to highest level

Parameter Number

Parameter Size

Parameter Name

Description

6 1 Scene controller. The parameter enables scene controller.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 1 No No No

From

 

To

Description

0   0 Disabled
1   1 Active (Default)

Parameter Number

Parameter Size

Parameter Name

Description

7 1 Switch ON level. The parameter defines the dimming level when restored from the OFF state by push button.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

0 0 99 No No No

From

 

To

Description

0   0 Restores last dim level (Default)
1   99 1% - 99%

Parameter Number

Parameter Size

Parameter Name

Description

8 1 Dimming Duration. The parameter defines how long it takes to dim to the desired level. Note! Only Multilevel Switch Command Class is affected by this parameter.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

1 0 255 No No No

From

 

To

Description

0   0 Disabled
1   127 Duration in seconds (1 - 127 seconds. Default is 1)
128   255 Duration in minutes (1 - 127 minutes)

Parameter Number

Parameter Size

Parameter Name

Description

9 2 Meter Report Interval. The parameter defines the report interval for Power Metering.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

60 0 32767 No No No

From

 

To

Description

0   0 Disabled
30   32767 Duration in seconds (30 - 32 767. Default is 60)