TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Heavy Duty Smart Switch Gen5 (ZW078-F)

Z-Wave Certification Number: ZC10-19036399


Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Reset the parameters 101-103 0
(Default)
Reset the parameters 101-103.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 To set which report would be sent in Report group 1 1 Send Meter Report of Voltage
  2 Send Meter Report of Current
  4
(Default)
Send Meter Report of Watt
  8 Send Meter Report of kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which report would be sent in Report group 2 1 Send Meter Report of Voltage
  2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8
(Default)
Send Meter Report of kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 To set which report would be sent in Report group 3 1 Send Meter Report of Voltage
  2 Send Meter Report of Current
  4 Send Meter Report of Watt
  8 Send Meter Report of kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 1 Reset the parameters 111-113 0
(Default)
Reset the parameters 111-113 to default values.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the time interval of sending Report 1 to 2147483647
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the time interval of sending Report 1 to 2147483647
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the time interval of sending Report 1 to 2147483647
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Configure the output load status after re-power on 0
(Default)
The last status before the power outage.
  1 Always on
  2 Always off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

200 1 Partner ID 0
(Default)
Aeon Labs Standard Product
  1 to 127 Others

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/disable Configuration Locked 0
(Default)
Disable
  1 Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 1 Reset the Smart Switch 6 1 Reset all configuration parameters to default.
  1431655765 Reset the Smart Switch to factory default

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Current Overload Protection. 0
(Default)
Disabled
  1 Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 To set which notification would be sent to the associated nodes in association group 1 0
(Default)
Nothing
  1 Hail CC
  2 Basic Report CC

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Enable/disable the parameter 91 and 92 0 Disable
  1
(Default)
Enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

91 2 Induce an automatic report 0 to 32767
(Default)
The threshold can be set from 0 to 32767 watt.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

92 1 Induce an automatic report 0 to 100
(Default)