TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Silent Mode on/off | 1 to 3 (Default) |
Level | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | One Touch Locking | -128 | One Touch Locking On | |
0 (Default) |
One Touch Locking Off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Lock Status LED | -128 | LED On | |
0 (Default) |
LED Off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Reset to Factory Defaults | -128 | Reset to Factory On | |
0 (Default) |
Reset to Factory Off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Auto Relock On/Off | -128 | Auto Relock On | |
0 (Default) |
Auto Relock Off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Auto Relock Time | 10 to 127 (Default) |
Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Wrong Code Entry Limit | 3 to 10 (Default) |
Times | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Shut Down Time (after wrong code entries) | 10 to 127 (Default) |
Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Operating Mode | 0 (Default) |
Normal Mode (Default) | |
1 | Vacation Mode (Keypad Locked Out) | ||||
2 | Privacy Mode (Keypad Locked, RF Unlock Functional) | ||||