Z-Wave Products

There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Roller Shutter 3 (FGR-223)

Z-Wave Certification Number: ZC10-19046413


Parameter Number

Parameter Size

Parameter Name

Parameter Values

150 1 Force calibration 0
(Default)
device is not calibrated
  1 device is calibrated
  2 force device calibration

Parameter Number

Parameter Size

Parameter Name

Parameter Values

151 1 Operating mode 1
(Default)
roller blind (with positioning)
  2 Venetian blind (with positioning)
  3 gate (without positioning)
  4 gate (with positioning)
  5 roller blind with built-in driver
  6 roller blind with built-in driver (impulse)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

152 4 Venetian blind - time of full turn of the slats 0 to 965535
(Default)
time of turn

Parameter Number

Parameter Size

Parameter Name

Parameter Values

153 1 Set slats back to previous position 0 slats return to previously set position only in case of the main controller operation.
  1
(Default)
slats return to previously set position in case of the main controller operation, momentary switch operation, or when the limit switch is reached.
  2 slats return to previously set position in case of the main controller operation, momentary switch operation, when the limit switch is reached or after receiving the Switch Multilevel Stop control frame

Parameter Number

Parameter Size

Parameter Name

Parameter Values

154 2 Delay motor stop after reaching end switch 0 to 255
(Default)
time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

155 2 Motor operation detection 0 reaching a limit switch will not be detected
  1 to 255
(Default)
report interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

156 4 Time of up movement 1 to 65535
(Default)
(0.01 - 655.35s, every 0.01s) - movement time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

157 4 Time of down movement 1 to 65535
(Default)
(0.01 - 655.35s, every 0.01s) - movement time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Switch type 0 momentary switches
  1 toggle switches
  2
(Default)
single, momentary switch (the switch should be connected to S1 terminal)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Inputs orientation 0
(Default)
default (S1 - 1st channel, S2 - 2nd channel)
  1 reversed (S1 - 2nd channel, S2 - 1st channel)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 Outputs orientation 0
(Default)
default (Q1 - 1st channel, Q2 - 2nd channel)
  1 reversed (Q1 - 2nd channel, Q2 - 1st channel)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 4 Alarm configuration - 1st slot 1 Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 action: 0- no action, 1-open blinds, 2-close blinds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

31 4 Alarm configuration - 2nd slot (Water) 1 Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 action: 0- no action, 1-open blinds, 2-close blinds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

32 4 Alarm configuration - 3rd slot (Smoke) 1 Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 action: 0- no action, 1-open blinds, 2-close blinds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

33 4 Alarm configuration - 4th slot (CO) 1 Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 action: 0- no action, 1-open blinds, 2-close blinds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

34 4 Alarm configuration - 5th slot (Heat) 1 Notification Type
  2 Notification Status
  3 Event/State Parameters
  4 action: 0- no action, 1-open blinds, 2-close blinds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 S1 switch - scenes sent 1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key hold down and key released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 1 S2 switch - scenes sent 1 Key pressed 1 time
  2 Key pressed 2 times
  4 Key pressed 3 times
  8 Key hold down and key released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 1 Measuring power consumed by the device itself 0
(Default)
function inactive
  1 function active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

61 2 Power reports - on change 0 reports are disabled
  1 to 500
(Default)
change in power

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 2 Power reports - periodic 0 periodic reports are disabled
  30 to 32400
(Default)
report interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

65 2 Energy reports - on change 0 reports are disabled
  1 to 500
(Default)
change in energy

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 Energy reports - periodic 0 periodic reports are disabled
  30 to 32400
(Default)
report interval