Z-Wave Products

There are over 4407 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: S100 Switch IO (China) (10003034-13X)

Z-Wave Certification Number: ZC10-19046455


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Association LED 0
(Default)
Turns the LED OFF
  255 Turns the LED ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Delay ON 0
(Default)
Disables timing
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
  128 to 254 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Activation TIME 0
(Default)
Disables timing
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
  128 to 254 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Behaviour of LED in repose 0
(Default)
LED OFF
  255 LED on at 20 percent of maximum level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Lock Input 0
(Default)
Unlock the direct control of load
  255 Lock the direct control of load

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Reset default 39015 Parameters, Groups, and Z-Wave status are restored to default value.
  17170 Parameters, except Lock long press are restored to default

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 1 Delay OFF 0
(Default)
Disables timing
  1 to 127 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
  128 to 254 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution

Parameter Number

Parameter Size

Parameter Name

Parameter Values

19 1 Press action 0
(Default)
When short press, device toggles the load
  1 When short press, device turns ON the load
  2 When short press, device turns OFF the load
  4 When short press, device turns ON the load. When hold press from 2 seconds to 10 seconds device turns OFF the load. The Slider does not works.With this configuration, the device will not send the Node Info neither Show the LEDs feedback with this press action

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Identify 255 the central LED blinks for 5 seconds in order to identify the device

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 State of charge 45056 Load is OFF
  45057 Load is ON
  45312 Load is OFF
  45567 Load is ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Calibration Required 0
(Default)
Calibration is not required
  255 It is necessary to calibrate the dimmer to work properly

Parameter Number

Parameter Size

Parameter Name

Parameter Values

27 1 Lock long press 0
(Default)
Long press works as described previously
  255 Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Calibration 1 Device performs calibration using Trailing and leading Edge and decides which one is better
  2 Device is calibrated using Trailing Edge.
  3 Device is calibrated using Leading Edge