There are over 4378 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Association LED | 0 (Default) |
Turns the LED OFF | |
255 | Turns the LED ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Behavior of LED in repose | 0 (Default) |
LED OFF | |
255 | LED on at 20 percent of maximum level | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Lock Input | 0 (Default) |
Unlock the direct control of load | |
255 | Lock the direct control of load | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 2 | Reset default | 39015 | Parameters, Groups, and Z-Wave status are restored to default value. | |
17170 | Parameters, except Lock long press are restored to default | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
18 | 1 | Manual association lock | 0 (Default) |
Unblocked | |
255 | Blocked | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
19 | 1 | Press action | 0 (Default) |
When short press, switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes. The Slider does not work. | |
1 | When short press, always activates those associated with the last power on by sending a Basic Set to 0xFF | ||||
2 | When short press, always deactivates associates by sending a Basic Set to 0x00 | ||||
4 | When short press, always activates the associated nodes by sending a Basic Set to 0xFFWhen hold press from 2 seconds to 10 seconds always turns off the associated nodes by sending a Basic Set to 0x00. Does not send Node Info nor does the central LED flash. | ||||
5 | The described actions are performed for value ‘0’, but sending the Multilevel Set | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Identify | 255 | the central LED blinks for 5 seconds in order to identify the device | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 2 | Device state | 45056 | Load is OFF | |
45057 | Load is ON | ||||
45312 | Lighting percentage level associated node | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
27 | 1 | Lock long press | 0 (Default) |
Long press works as described previously | |
255 | Long press from 2 seconds to 20 seconds does not send a Node info. With a long press above 30 seconds, all parameters except Lock long press are restored to default and device sends a Node Info. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
28 | 1 | Consult on Touch Detection | 0 (Default) |
If there is 1 Associated device, when Touch is detected, controlled device state will be consulted | |
255 | If there is 1 Associated device, when Touch is detected, controlled device state is not consulted. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
29 | 1 | Enable automatic reporting CENTRAL_SCENE | 0 (Default) |
Enables CC Central Scene Notification when there are no nodes associated with the control group and Inhibits error signaling by pressing less than 2 seconds if there are no associated nodes. | |
255 | Enables error signaling by pressing less than 2 seconds if there are no associated nodes | ||||