Z-Wave Products

There are over 4408 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Button (FGPB-101)

Z-Wave Certification Number: ZC10-19046421


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Scenes sent to the controller 1 Key Pressed 1 time
  2 Key Pressed 2 times
  4 Key Pressed 3 times
  8 Key Pressed 4 times
  16 Key Pressed 5 times
  32 Key Held Down
  64 Key Released

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Key Pressed 1 time – command sent to 2nd association group 0 no action
  1 SWITCH ON
  2 SWITCH OFF
  3
(Default)
SWITCH ON/OFF – alternately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Key Pressed 1 time – value of SWITCH ON command sent to 2nd association group 1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Key Pressed 2 times – command sent to 2nd association group 0 no action
  1
(Default)
SWITCH ON
  2 SWITCH OFF
  3 SWITCH ON/OFF – alternately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 2 Key Pressed 2 times – value of SWITCH ON command sent to 2nd association group 1 to 99
(Default)
forcing level of associated devices
  255 setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Key Pressed 3 times – command sent to 2nd association group 0
(Default)
no action
  1 SWITCH ON
  2 SWITCH OFF
  3 SWITCH ON/OFF – alternately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 2 Key Pressed 3 times – value of SWITCH ON command sent to 2nd association group 1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Key Pressed 1 time – command sent to 3rd association group 0 no action
  1 SWITCH ON
  2 SWITCH OFF
  3
(Default)
SWITCH ON/OFF – alternately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 2 Key Pressed 1 time – value of SWITCH ON command sent to 3rd association group 1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Key Pressed 2 times – command sent to 3rd association group 0 no action
  1
(Default)
SWITCH ON
  2 SWITCH OFF
  3 SWITCH ON/OFF – alternately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 2 Key Pressed 2 times – value of SWITCH ON command sent to 3rd association group 1 to 99
(Default)
forcing level of associated devices
  255 setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 Key Pressed 3 times – command sent to 3rd association group 0
(Default)
no action
  1 SWITCH ON
  2 SWITCH OFF
  3 SWITCH ON/OFF – alternately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 2 Key Pressed 3 times – value of SWITCH ON command sent to 3rd association group 1 to 99 forcing level of associated devices
  255
(Default)
setting associated devices to the last remembered state or turning them on

Parameter Number

Parameter Size

Parameter Name

Parameter Values

29 1 Key Held Down – command sent to 3rd association group 0 no action
  1 START LEVEL CHANGE UP (brightening)
  2 START LEVEL CHANGE DOWN (dimming)
  3
(Default)
START LEVEL CHANGE UP/DOWN (brightening/dimming) – alternately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Associations in Z-Wave network security mode 1 2nd group sent as secure
  2 3rd group sent as secure
  4 4th group sent as secure

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Alarm frame triggers 1 Key Pressed 1 time
  2 Key Pressed 2 times
  4 Key Pressed 3 times
  8 Key Pressed 4 times
  16 Key Pressed 5 times
  32 Key Held Down
  64 Key Released