Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
1 | 2 | Heartbeat rate | If the notification System Heartbeat is on, a notification report System Heartbeat is sent periodically every 60 minutes (default value). | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
60 | 1 | 1440 | No | No | No |
From |
To |
Description |
|||
1 | 1440 | Heartbeat rate [min] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
10 | 2 | Send Interval Power Output 2 | Period with which the power of output 2 is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 120 | No | No | No |
From |
To |
Description |
|||
1 | 120 | Interval power [min] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
11 | 2 | Minimum Delta Power Send Output 2 | When the power of output 2 changes this anount the energy value is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 100 | No | No | No |
From |
To |
Description |
|||
1 | 100 | Minimum delta power [%] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
2 | 2 | Main Voltage | Together with the mesured current and the Phase shift configuration parameter the Main Voltage confirguation parameter is used to calculate the power of the oututs. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
230 | 20 | 280 | No | No | No |
From |
To |
Description |
|||
20 | 280 | Main voltage [V] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
3 | 2 | Phase shift - cosines (phi) | Together with the mesured current and the Main Voltage configuration parameter the Phase shift configruation parameter is used to calculate the power of the oututs. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
100 | 0 | 100 | No | No | No |
From |
To |
Description |
|||
0 | 100 | Phase shift [0.01] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
4 | 2 | Send Interval Energy Output 1 | Period with which the energy of output 1 is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 120 | No | No | No |
From |
To |
Description |
|||
1 | 120 | Interval energy [min] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
5 | 2 | Minimum Delta Energy Send Output 1 | When the energy of output 1 changes this anount the energy value is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2000 | 1 | 50000 | No | No | No |
From |
To |
Description |
|||
1 | 50000 | Minimum delta energy [0.001 kWh] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
6 | 2 | Send Interval Power Output 1 | Period with which the power of output 1 is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 120 | No | No | No |
From |
To |
Description |
|||
1 | 120 | Interval power [min] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
7 | 2 | Minimum Delta Power Send Output 1 | When the power of output 1 changes this anount the energy value is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 100 | No | No | No |
From |
To |
Description |
|||
1 | 100 | Minimum dleta power [%] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
8 | 2 | Send Interval Energy Output 2 | Period with which the energy of output 2 is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
5 | 1 | 120 | No | No | No |
From |
To |
Description |
|||
1 | 120 | Interval energy [min] | |||
Parameter Number |
Parameter Size |
Parameter Name |
Description |
||
9 | 2 | Minimum Delta Energy Output 2 | When the energy of output 2 changes this anount the energy value is sent by a Meter Report. | ||
Default Value |
Minimum Value |
Maximum Value |
Read Only |
Re-Inclusion |
Advanced |
2000 | 1 | 50000 | No | No | No |
From |
To |
Description |
|||
1 | 50000 | Minimum delta energy [0.001 kWh] | |||