Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Radio Switch Dual (MTSWI-100-WL)

Z-Wave Certification Number: ZC10-19086712


Parameter Number

Parameter Size

Parameter Name

Description

1 2 Heartbeat rate If the notification System Heartbeat is on, a notification report System Heartbeat is sent periodically every 60 minutes (default value).

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

60 1 1440 No No No

From

 

To

Description

1   1440 Heartbeat rate [min]

Parameter Number

Parameter Size

Parameter Name

Description

10 2 Send Interval Power Output 2 Period with which the power of output 2 is sent by a Meter Report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 120 No No No

From

 

To

Description

1   120 Interval power [min]

Parameter Number

Parameter Size

Parameter Name

Description

11 2 Minimum Delta Power Send Output 2 When the power of output 2 changes this anount the energy value is sent by a Meter Report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 100 No No No

From

 

To

Description

1   100 Minimum delta power [%]

Parameter Number

Parameter Size

Parameter Name

Description

2 2 Main Voltage Together with the mesured current and the Phase shift configuration parameter the Main Voltage confirguation parameter is used to calculate the power of the oututs.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

230 20 280 No No No

From

 

To

Description

20   280 Main voltage [V]

Parameter Number

Parameter Size

Parameter Name

Description

3 2 Phase shift - cosines (phi) Together with the mesured current and the Main Voltage configuration parameter the Phase shift configruation parameter is used to calculate the power of the oututs.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

100 0 100 No No No

From

 

To

Description

0   100 Phase shift [0.01]

Parameter Number

Parameter Size

Parameter Name

Description

4 2 Send Interval Energy Output 1 Period with which the energy of output 1 is sent by a Meter Report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 120 No No No

From

 

To

Description

1   120 Interval energy [min]

Parameter Number

Parameter Size

Parameter Name

Description

5 2 Minimum Delta Energy Send Output 1 When the energy of output 1 changes this anount the energy value is sent by a Meter Report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2000 1 50000 No No No

From

 

To

Description

1   50000 Minimum delta energy [0.001 kWh]

Parameter Number

Parameter Size

Parameter Name

Description

6 2 Send Interval Power Output 1 Period with which the power of output 1 is sent by a Meter Report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 120 No No No

From

 

To

Description

1   120 Interval power [min]

Parameter Number

Parameter Size

Parameter Name

Description

7 2 Minimum Delta Power Send Output 1 When the power of output 1 changes this anount the energy value is sent by a Meter Report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 100 No No No

From

 

To

Description

1   100 Minimum dleta power [%]

Parameter Number

Parameter Size

Parameter Name

Description

8 2 Send Interval Energy Output 2 Period with which the energy of output 2 is sent by a Meter Report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

5 1 120 No No No

From

 

To

Description

1   120 Interval energy [min]

Parameter Number

Parameter Size

Parameter Name

Description

9 2 Minimum Delta Energy Output 2 When the energy of output 2 changes this anount the energy value is sent by a Meter Report.

Default Value

Minimum Value

Maximum Value

Read Only

Re-Inclusion

Advanced

2000 1 50000 No No No

From

 

To

Description

1   50000 Minimum delta energy [0.001 kWh]