There are over 4391 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Curtain Motor Controller (SR-ZV9080A-A)

Z-Wave Certification Number: ZC10-19046460


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Power change absolute threshold report, unit is W 0 disable absolute threshold report function
  1 to 100
(Default)
value of the power change absolute threshold, if power change value is over the threshold value, report the power change value using METER_REPORT

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Current change absolute threshold, unit is 0.1A 0
(Default)
disable absolute threshold function
  1 to 10 value of the current change absolute threshold, if current change value is over the threshold value, report the current change value using METER_REPORT

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Voltage change absolute threshold, unit is 1V 0
(Default)
disable absolute threshold function
  1 value of the voltage change absolute threshold, if voltage change value is over the threshold value, report the voltage change value using METER_REPORT

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Slats rotation time, unit is 0.1S 0 disable the function
  5 to 250
(Default)
value of the slats rotation time This parameter is only valid when parameter 3 is configured as venetian mode (up/down and slats rotation).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 4 Time cycle to report the values of energy consumption, voltage, current and load power actively 60 to 2678400
(Default)
value of the time cycle, unit is S.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Saving load state before power failure 0 disable to report actively
  1
(Default)
value to report, unit is one percent

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Working mode 0 light mode
  1 Shutter mode without positioning
  2
(Default)
Shutter mode with positioning
  3 venetian mode (up/down and slats rotation)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Enable/disable to save positioning 0 disable
  1
(Default)
enable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Enable/disable over current protection 0 disable
  1
(Default)
enable, when over current detected, there are two methods to cancel alarm: 1. short press either switch button S1 or S2, the alarm will last at least 1 minute and then be cancelled. 2. re-power on the curtain motor controller

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 starting positioning calibration 0
(Default)
positioning not calibrated
  1 positioning calibration completed

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 When parameter 3 value configured as 0 (light mode), configuration of button S1 and S2 control. 0
(Default)
Short press S1 to switch ON/OFF Q1. Press and hold down S1 to switch ON Q1, then release to switch OFF Q2. Short press S2 to switch ON/OFF Q2. Press and hold down S2 to switch ON Q2, then release to switch OFF Q2.
  1 Short press S1 to switch ON/OFF Q1. When S1 is pressed and held down, then released, not processed. Short press S2 to switch ON/OFF Q2. When S2 pressed and held down, then released, not processed.
  2 Press and hold down S1 to switch ON Q1, then release to switch OFF Q2. When S1 short pressed, not processed. Press and hold down S2 to switch ON Q2, then release to switch OFF Q2. When S2 short pressed, not processed.
  3 Short press S1 or S2 to switch ON/OFF of both Q1 and Q2 simultaneously. When S1 or S2 pressed and held down, not processed
  4 Press and hold down S1 to switch ON Q1 and Q2. When S1 short pressed, not processed. Press and hold down S2 to switch OFF Q1 and Q2. When S2 short pressed, not processed.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Enable/disable to add the device to or remove it from a Z-Wave network through button S1. 0 enable
  1
(Default)
disable

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Enable/disable to send scene activation command CENTRAL_ SCENE_ NOTIFICATION_ V3 when the switches S1 and S2 are pressed. 0 disable to send for action of both S1 and S2
  1
(Default)
enable to send for action of both S1 and S2
  2 enable to send for action of only S1
  3 enable to send for action of only S2