There are over 4395 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Sensor Operation Mode | 0 (Default) |
Internal Magnet Sensor Used | |
1 | External Terminal Inputs Used | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Time Delay of ‘Off‘ command frame | 0 to 32400 (Default) |
seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Delay of Tamper Alarm Cancellation | 0 to 32400 (Default) |
seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Reporting Tamper Alarm Cancellation | 0 | Do not send Report | |
1 (Default) |
Send Report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Central Scene Event Functionality | 0 (Default) |
Disabled | |
1 | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Tilt Sensor Functionality | 0 | Disabled | |
1 (Default) |
Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Sensor State Polarity | 0 (Default) |
Closed when Magnet in proximity | |
1 | Opened when Magnet in proximity | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Visual LED Indications | 1 | No Indications | |
2 | Open/Close Status Change | ||||
4 | Wake Up | ||||
16 | Device Tampering | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Range Test after double click | 0 (Default) |
Disabled | |
1 | Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | 2nd Association Group Trigger | 0 (Default) |
Switch after ‘Open‘ and ‘Close‘ | |
1 | Switch after ‘Open‘ | ||||
2 | Switch after ‘Close‘ | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Command Sent to Devices of Association Group 2 | 0 | On | |
1 | Off | ||||
2 (Default) |
On and Off | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | BASIC command value sent to 2nd Association Group on ‘On‘ event | 0 to 99 | Value | |
-1 (Default) |
Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | BASIC command value sent to 2nd Association Group on ‘Off‘ event | 0 to 99 (Default) |
Value | |
-1 | Value | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | Time Delay of ‘Off‘ command frame | 0 to 32400 (Default) |
seconds | |